background image

BatteryMINDer

®    

Model 483CEC1

Rev. A-051216 

Page 19 

P/N 483CEC1-MNL

FOR REPAIR OR REPLACEMENT

All returns must be authorized by VDC Electronics.

In the event that you believe your product may be defective, you MUST speak 

to a VDC Electronics technician at 

1-800-379-5579 x6

 (M - F, ET) before 

proceeding further.  If you must return the unit, the technician will give you 

an 

RMA

 #.  Please use Return Form found on 

batteryminders.com/ 

under 

Shipping & Returns

 when returning your product.  

BatteryMINDer

 

Model 

483CEC1

Serial Number 

 

___________________________

Place of purchase 

___________________________

Date of purchase  

___________________________

RMA# ___________________________

Please register your unit on-line within 10 days of 

purchase.  

Due to the ever-changing technology 

associated with this 

BatteryMINDer

®

 unit, we may be 

unable to keep you informed of significant upgrades, 

changes, etc. without your registration.

  The information 

you provide upon registration will be used to keep a 

record of your purchase and will assist in providing 

support should you ever need to contact our 

Technical Service department:

[email protected]; 800-379-5579 x6 (ET). 

IMPORTANT NOTICE

BatteryMINDer

®

 

Five-Year Warranty Registration

batteryminders.com/ 

under 

Registration

NOTES

___________________________________________________
___________________________________________________
___________________________________________________

Содержание 483CEC1

Страница 1: ...43 www BatteryMINDers com techsupport vdcelectronics com BatteryMINDer COMMERCIAL 48 Volt Model 483CEC1 Battery Maintainer Charger Desulfator INSTRUCTION MANUAL Includes ATS Temperature Sensor install...

Страница 2: ...ate crystals build up in the plates The large sulfate crystals increase the resistance of the plates and makes the battery harder to recharge and reduces the amount of power that can be drawn from the...

Страница 3: ...pull by plug rather than cord when disconnecting maintenance charger Make sure cord is located so that it will not be stepped on tripped over or otherwise subjected to damage or stress 6 An extension...

Страница 4: ...unning cold water for at least 10 minutes and get medical attention immediately 5 NEVER smoke or allow a spark or flame in vicinity of battery 6 Be extra cautious to reduce risk of dropping a metal to...

Страница 5: ...attery will corrode and damage maintenance charger 3 Never allow battery acid to drip on maintenance charger when reading electrolyte specific gravity or filling battery 4 Do not operate maintenance c...

Страница 6: ...s that could have caused sulfation such as high temperature storage 80 F and or allowed to self discharge to 2 06 Volts cell 49 4V battery set even before you purchased it then you can disregard our r...

Страница 7: ...batteries have no filler caps or manifold type covers Because you cannot gain access to the interior of your battery you cannot test it with a hydrometer USE A DIGITAL VOLTMETER ONLY 1 Recharge the ba...

Страница 8: ...Connection Precautions Unit Location and Qualifying Your Battery Set BEFORE proceeding further 1 Install Ring Terminal Assembly RTA 2415 to the first and last battery in the series connected 48 V gro...

Страница 9: ...Temperature Sensor input connector with ATS 1 Ambient Temperature Sensor installed included 5 Output cord with quick connect plug 6 Ring Terminal cordset with quick connect plug included 7 Mounting t...

Страница 10: ...ING ECO mode no battery set connected very low standby power mode None required 3B BATTERY WEAK Battery set s voltage is low at start of charge OR voltage is low after testing stage Allow BatteryMINDe...

Страница 11: ...BatteryMINDer Model 483CEC1 Rev A 051216 Page 11 P N 483CEC1 MNL BatteryMINDer 483CEC1 Unit Label close up VDC 483CEC1 LABEL P N 701 100476 01 R 2 1 3 A A D C B D C B E G F...

Страница 12: ...mperature 27 C 80 F Blue Steady Ambient temperature 21 C 70 F VOLTAGE LOW AMBER REJECTED RED Initial qualification of the battery set s condition at the beginning of Soft Start stage Amber Steady Volt...

Страница 13: ...monitors the battery set and adjusts its output several times a second Indicator Light Details Power light is GREEN anytime the maintenance charger is plugged into AC Power Battery Connection light i...

Страница 14: ...er and three times the life of conventional batteries The Wet cell comes in two styles Serviceable and Maintenance free Both are filled with electrolyte and are basically the same AGM absorbed glass m...

Страница 15: ...lk LED Indicator will light GREEN The maintenance charger will now begin charging by first checking the battery set to determine its voltage and ability to accept a charge Should the battery set not h...

Страница 16: ...rcentage 48V 51 6 52 4 100 50 4 51 6 75 49 6 50 4 50 48 8 49 6 25 48 0 48 8 0 44 shorted EZC 01 Installation The EZC 01 Connector is universal flush mountable for use on any BatteryMINDer Charger Main...

Страница 17: ...safely discarded recycled Battery Set Weak Indicator lights RED blinking Battery set may be weak heavily sulfated or too large to fully charge before unit times out Battery set may be so large it may...

Страница 18: ...___________________________________________________ _______________________________________________________ _______________________________________________________ ____________________________________...

Страница 19: ..._________________________ RMA ___________________________ Please register your unit on line within 10 days of purchase Due to the ever changing technology associated with this BatteryMINDer unit we ma...

Страница 20: ...our BatteryMINDer product is warrantied for FIVE years from date of purchase at retail against defective material or workmanship We make no warranty other than this limited warranty and expressly excl...

Отзывы: