BatteryMINDer
®
Model 483CEC1
Rev. A-051216
Page 10
P/N 483CEC1-MNL
BatteryMINDer 483CEC1 Features
Con't. from Previous Table
Meaning
Action
2A
VOLTAGE:
LOW
,
REJECTED
Start of charge
AMBER
STEADY ON
= battery set fully discharged.
RED
FLASHING = Battery set's
voltage is near zero volts.
Allow BatteryMINDer to try to
restore battery set.
2B
Battery set is being constant current
charged to about 80%.
Allow BatteryMINDer to charge
battery set.
2C
Battery set is being constant voltage
charged to about 95%.
Allow BatteryMINDer to charge
battery set.
2D
Maintenance mode. Battery set is
being topped off to 100%.
Allow BatteryMINDer to
maintain and desulfate battery
set indefinitely.
3A
POWER
GREEN
STEADY = AC power
connected.
GREEN
FLASHING = ECO mode
(no battery set connected, very low
standby power mode).
None required.
3B
BATTERY WEAK
Battery set's voltage is low at start of
charge OR voltage is low after testing
stage.
Allow BatteryMINDer to attempt
to restore battery set if low at
start of charge. Replace battery
set if voltage is low after testing
stage.
3C
BAD CELL
RED
FLASHING = one or more cells of
the battery set are dead.
Battery set must be replaced.
3D
DESULFATING
FLASHING = battery set is being
desulfated.
None required.
3E
BATTERY
CONNECTION
GREEN
STEADY = battery set
connected properly.
RED
STEADY = battery set connect
improperly.
If needed, correct battery set
connection.
3F
TESTING
BLUE
STEADY = test in progress,
pause in charging. (Tests to see if
battery set holds charge.)
None possible.
3G
TEMPERATURE
COMPENSATION
Meaning:
BLUE
STEADY = cold
temperature compensation being
applied.
GREEN
STEADY = hot temperature
compensation being applied.
None required.