BatteryMINDer
®
Model 483CEC1
Rev. A-051216
Page 12
P/N 483CEC1-MNL
LED INDICATION TABLE
POWER
GREEN
Green Steady
AC power connected
Green Flashing
ECO mode
BATTERY CONNECTION
GREEN
RED
Green Steady
Battery set connected correctly
Red Steady
Battery set connected incorrectly
BATTERY WEAK
AMBER
Amber Steady
Battery set requires soft-start charging or battery set's voltage
is < 50.0V after analysis stage
BAD CELL
RED
Red Flashing
Battery set's voltage is < 46.0V after analysis stage
TESTING
BLUE
Blue Steady
Analysis stage
DESULFATING
BLUE
Blue Flashing
Desulfating pulses are in process
TEMPERATURE COMPENSATION
GREEN
BLUE
Green Steady
Ambient temperature > 27°C/80°F
Blue Steady
Ambient temperature < 21°C/70°F
VOLTAGE LOW
AMBER
REJECTED
RED
Initial qualification of the battery set's condition (at the beginning of Soft-Start stage)
Amber Steady
Voltage: 12V - 42V
Red Flashing
Voltage: < 12V (Low Voltage)
Charging Stages
• Soft-Start
is used if a battery set’s voltage is under 42V when charging
begins. It uses a low constant current to slowly bring up voltage. This
prepares a weak or neglected battery set for the Constant Current stage.
• Constant Current
(sometimes called Bulk) is the main charging stage.
The maintenance-charger puts out a constant current of 3A, its maximum
current. Battery set's voltage rises until the battery set reaches the
optimal charging voltage.
• Constant Voltage
(sometimes called Absorption) is the second charging
stage. The maintenance-charger regulates the current given to the