![Basler Vision Technologies Sprint Series Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/basler-vision-technologies/sprint-series/sprint-series_user-manual_2707562086.webp)
Exposure Start and Exposure Time Control
76
Basler sprint Mono Cameras
AOI Length
is the length of the AOI based on the current AOI length setting (see
)
p = 0 if the line stamp feature is not enabled (see Section 6.5 on
p = 16 when the line stamp feature is enabled
Formula 4
calculates the maximum line rate based on the amount of time it takes to transmit the
pixel data for an acquired line from the camera to the host PC:
Where:
CL Clk
is the Camera Link clock speed for your camera model as stated in Table 8 on
Taps
is the number of taps being used as determined by the current video data output
mode setting (see Chapter 5 on
AOI Length
is the length of the AOI based on the current AOI length setting (see
)
p = 0 if the line stamp feature is not enabled (see Section 6.5 on
p = 16 when the line stamp feature is enabled
includes an example that illustrates how to use these formulas to
determine the maximum allowed line rate.
Once you have determined the maximum allowed line rate, you can easily determine the minimum
allowed line period:
Max Lines / s
CL Clk
Taps
×
12
Taps
×
(
)
AOI Length
p
+
+
-----------------------------------------------------------------------------
=
Min Line Period
1
Max Line Rate
--------------------------------------
=
Содержание Sprint Series
Страница 4: ......
Страница 10: ...Table of Contents vi Basler sprint Mono Cameras...
Страница 42: ...Physical Interface 32 Basler sprint Mono Cameras Fig 14 Camera Frame Grabber Interface...
Страница 48: ...Physical Interface 38 Basler sprint Mono Cameras...
Страница 76: ...Line Acquisition Modes 66 Basler sprint Mono Cameras...
Страница 94: ...Exposure Start and Exposure Time Control 84 Basler sprint Mono Cameras...
Страница 230: ...Revision History 220 Basler sprint Mono Cameras...
Страница 232: ...Feedback 222 Basler sprint Mono Cameras...