![Basler Vision Technologies Sprint Series Скачать руководство пользователя страница 183](http://html1.mh-extra.com/html/basler-vision-technologies/sprint-series/sprint-series_user-manual_2707562183.webp)
Configuring the Camera
Basler sprint Mono Cameras
173
Gain CSR
Note:
The gain can be set by writing a floating point value to the Absolute Gain field or by writing
an integer value to the Raw Gain field. See Section 7.2.2.1 on
for an explanation of the
difference between these two fields.
Register Base Address: 0x0E00
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control and status register:
0x00 = The register is not available
0x01 = The register is available and all related settings are OK
0x80 = A value in the register is set out of range
Field Name:
Absolute Gain
Offset
: 0x0001
Size:
4 Bytes
Type
: Read/Write
Description:
Writing a floating point value to this field sets the gain in dB.
The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.
for more information about gain.
Field Name:
Absolute Min
Offset
: 0x0005
Size:
4 Bytes
Type
: Read only
Description:
Minimum allowed floating point value for the absolute gain setting.
The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.
Field Name:
Absolute Max
Offset
: 0x0009
Size:
4 Bytes
Type
: Read only
Description:
Maximum allowed floating point value for the absolute gain setting.
The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.
Field Name:
Raw Gain
Offset
: 0x000D
Size:
2 Bytes
Type
: Read/Write
Description:
Writing an integer value to this field sets the gain.
The dB of gain that the camera will achieve at a given setting is determined by the formula shown
in Section 6.1 on
.
The bytes in this field are interpreted as follows:
Byte 1 = Low byte of the raw value
Byte 2 = High byte of the raw value
Field Name:
Raw Min
Offset
: 0x000F
Size:
2 Bytes
Type
: Read only
Description:
Minimum allowed integer value for the raw gain setting.
The bytes in this field are interpreted as follows:
Byte 1 = Low byte of the min value
Byte 2 = High byte of the min value
Field Name:
Raw Max
Offset
: 0x0011
Size:
2 Bytes
Type
: Read only
Description:
Maximum allowed integer value for the raw gain setting.
The bytes in this field are interpreted as follows:
Byte 1 = Low byte of the max value
Byte 2 = High byte of the max value
Содержание Sprint Series
Страница 4: ......
Страница 10: ...Table of Contents vi Basler sprint Mono Cameras...
Страница 42: ...Physical Interface 32 Basler sprint Mono Cameras Fig 14 Camera Frame Grabber Interface...
Страница 48: ...Physical Interface 38 Basler sprint Mono Cameras...
Страница 76: ...Line Acquisition Modes 66 Basler sprint Mono Cameras...
Страница 94: ...Exposure Start and Exposure Time Control 84 Basler sprint Mono Cameras...
Страница 230: ...Revision History 220 Basler sprint Mono Cameras...
Страница 232: ...Feedback 222 Basler sprint Mono Cameras...