4
2. Product Specifications
General Specifications
Operating Temperature
0 to 70°C
Storage Temperature
-20 to 90°C
Humidity
5 to 95% (non-condensing)
Environmental Air
No corrosive gasses permitted
Agency Approvals
CE EN61010-1, CB IEC61010-01, EMC
EN61326-1, Pending UL 61010-01 and CSA
C22.2 61010-1
Mechanical/Certifications
Size: H x W x D
63.5mm x 173mm x 90mm, 2.5" x 6.8" x 3.55"
Weight with 4-20mA output option
900g, 32oz
Weight without 4-20mA output option
725g, 26oz
DIN Rail Mount
35mm rail
Input Power
Input Voltage Range
+24VDC (+20VDC to +30VDC)
Power Consumption with 8 Pyrometers
14.0 watts, 600mA (+24VDC)
Pin Assignments
Pin 1 +V
Pin 2
-V circuit ground
Pin 3 earth/chassis ground
Terminal Type - Removable
3 pin, 5.00/5.08mm plug
NOTE:
Relay drive current (17mA for each relay) is not factored into power rating because
relays are only active during an error condition. When active, the system shuts down power to
the pyrometers causing power consumption to drop.
Relays
Number of Outputs
2
Type of Output
2 - Form-C (NO/COM/NC)
Maximum Switching Voltage
300V AC/DC
Contact Current Rating
8A at 24VDC
Maximum Inrush Current
15A (300 ms)
Minimum Load Current
20mA at 24VDC
Rated Carry Current
8A (70°C)/5A (85°C)
Interrupting Rating (ohmic load) max.
190W (24 VDC)
85W (48 VDC)
Fuse
No fuse
Commons
2 Isolated
Pin Assignments
Pin 1 NO
Pin 2 COM
Pin 3 NC
Terminal Type - Removable
3 pin, 5.00/5.08mm plug
Содержание EXACTUS IFM8-I
Страница 4: ...3 Figure 1 2 IFM8 IA Overview...
Страница 10: ...9 c The following screen Figure 4 3 will appear Click the Properties button Figure 4 3...
Страница 15: ...14 Figure 4 10 Check the Echo typed characters locally check box and close the dialog windows Figure 4 11...
Страница 18: ...17 Figure 6 1 Alarm configuration menu Figure 6 2 Pyrometer Internal Temperature Alarm Configuration Menu...