Serial input:
<
Multitouch_Long_Message$
>
Sends text label for display when the Multitouch Long Press is
activated.
Serial output:
<
Status$
>
After power cycle of the keypad, this string reports the keypad’s
software version.
If an invalid string is received on the <
Configuration$
> input, an
error message will be displayed on this output.
Serial output:
<
Temperature$
>
Reports the ambient room temperature in following format “xx.x”.
Depending of the report type, the temperature will be updated every
60 seconds, or on every temperature change of 0.5° Celsius. (equal to
0.9° Fahrenheit)
The temperature report type can be set using the
‘
Basalte Deseo
Configuration
’ module.
Serial output:
<
Humidity$
>
Reports the relative humidity
in following format “xx.x”.
Depending of the report type, the temperature will be updated every
60 seconds, or on every temperature change of 1% Humidity.
The humidity report type can be set using the
‘
Basalte Deseo
Configuration
’ module.
Serial input:
<
Configuration$
>
Needs to be connected to the serial output <
Initialize_To_Device$
>
on the ‘
Basalte Deseo Configuration
’ module
.