EN
page 52
Rinse-aid level warning (option).
When the
F19
indicator
fl
ashes on the display it means that the rinse-aid is over (only
on machines equipped with the optional "Chemicals level Sensor").
Flowmeter failure warning (option).
When the
F9
symbol appears on the display it means that no passage of water is
detected and the inlet water temperature probe is damage or is disconnected (only on machines equipped with the optional
“Flowmeter” installed and enabled, after the water
fi
lling or the rinse). By pressing both the key
A
and
C
for about 10 seconds
the message
Err FLuS
appears
.
Water probe failure (option).
By pressing both the key
A
and
C
for about 3 seconds it is possible to check the machine
inlet water temperature (only on machines equipped with the optional “Loading water probe” installed and enabled). If the
water probe is damage or disconnected the message
FAIL 000°C
appears.
8.2 Alarms
The alarms are displayed, based upon their meaning.
If an alarm occurs the machine stops.
TYPE OF ALARM
CAUSE
B2
BOILER PROBE FAILED
B3
BOILER HEATING ALARM
B4
FAILURE RINSING
B5
BOILER OVERHEATING
B9
BOILER SAFETY THERMOSTAT
E1
WATER LOAD FAILED
E2
TANK PROBE FAILED
E3
TANK HEATING ALARM
E5
TANK OVERHEATING
E6
TANK DRAINING FAILED
E8
TANK SAFETY THERMOSTAT
Z6
TANK LOW LEVEL
Z9
REGENERATION FAILED
!
!