- 58 -
The electric installation must have appropriate earthing, conforming to the valid regulations.
The safety of the electric installation may be assured only when that installation fulfils the
requirements of the standards.
Before connecting the device make sure that the voltage and frequency values on the
rating plate are consistent with the existing electric installation.
The allowable voltage
deviation is ±10%.
In order to connect the device directly to the power supply it is required to install the
interrupting switch between the device and the installation, suitable for the power. The
contacts of that switch must have the gap appropriate for the installation instructions,
assuring full disconnection in the overvoltage category III. The interrupting switch
should be installed in a place always accessible for the personnel.
Position the main switch, connected to the supply
cable, in
„0“
(zero) position. Check if the cable
section is suitable for the power consumed by the
device.
The power supply values are specified in the table
below:
400 V 3N 50/60 Hz
230 V 3 50/60 Hz
230 V 50/60 Hz
230 V 2 50/60 Hz
208 V 3 50/60 Hz
208 V 2 50/60 Hz
117161/
T6110
5 x 2.5 mm
2
4 x 2,5 mm
2
3 x 6 mm
2
//
4 x 12 AWG
//
117101/
T10110
5 x 4 mm
2
4 x 6 mm
2
//
//
4 x 8 AWG
//
Fig. 6