- 57 -
Before connection flush the system with sufficient
amount of water in order to remove any iron
particles.
Connect
„Aqua“
connection to appropriate
installation of cold water supply with installed
cut-off valve and filter.
Make sure that the valve is installed in easily
accessible place.
Caution:
In case of water supply hose damage
replace it with new one, do not reuse old hose.
5.4 Drain connection
Water flowing from the device drain may be hot
(90°C), therefore the drain hoses should be
resistant to such temperature.
The water drain is located in the bottom back
section of the device and is equipped with
connection pipe (Ø 40 mm).
Connect the pipe with the drain element (
fig. 5,
pos. A
).
The drain element is the water seal. However we
recommend to connect the drain pipe with open
funnel.
Check if the internal water seal is filled with water,
and if not, fill it through the drain in the device
chamber.
5.5 Electric connection
WARNING! Electric shock hazard!
The device can cause injuries due to improper installation!
Before installation and connecting the local power grid specification should be
compared with that of the device (see type label).
Connect the device only in case of compliance!
Fig. 5
Fig. 4