Installation Instructions
22 / 68
117910
EN
• The 5-pin socket must be fixed to the wall close to where the oven is installed
and should be easily accessible.
According to the regulations, the distance between the contacts in the open
position must be at least 3 mm. A standardised connection cable with rubber
insulation, which is supplied with the oven, must be used to connect the
appliance correctly to the 5-pin plug. If the appliance is installed in countries with
a different power supply, the cable cross-section will increase accordingly and
the cable will need to be replaced.
• The appliance must be earthed in accordance with the safety regulations for
electrical equipment.
• Potential equalisation is carried out at the screw marked
, which is located
under the cable gland for the electrical connection at the rear of the appliance.
• A separate 5-core cable must be provided for the appliance from the 5-pin
socket in the wall to the facility's control cabinet, and its cross-section must
correspond to the maximum electrical power of the appliance with adequate
protection provided by an automatic circuit breaker.
Fig. 4