GAS FRY TOPS 

ELECTRIC FRY TOPS 

SERIES 70

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 

INSTALLATION, USE 
AND MAINTENANCE 

 

286506 

286508  2855051  2855071 

286507 

286509  2855061  2855081 

GB/UK 

Содержание 70 Series

Страница 1: ...Pag 22 50 GAS FRY TOPS ELECTRIC FRY TOPS SERIES 70 INSTALLATION USE AND MAINTENANCE 286506 286508 2855051 2855071 286507 286509 2855061 2855081 GB UK...

Страница 2: ...5081 G gas gaz Fig Abb 1 Dimensioni Dimensions Floor space dimensions Raumbedarfsmasse Espacio m ximo necesario 285606 286508 286507 286509 Fig Abb 4 Dimensioni Dimensions Floor space dimensions Raumb...

Страница 3: ...50 20 20 DE ART II2H3B P p mbar 50 50 20 AT CH CZ SK N II2H3B P p mbar 28 30 28 30 20 FI LT BG kW B II2H3B P p mbar 28 30 28 30 20 NO SK RO Qn m h C II2H3B P p mbar 28 30 28 30 20 EE SI HR TR kg h D...

Страница 4: ...ruciatore Changement du gicleur du br leur Substituting the burner nozzle Austausch der Hauptbrennerd se Cambio boquilla quemador Fig Abb 13 Regolazione dell aria primaria bruciatore R glage de l air...

Страница 5: ...nstruction for use Electric fry tops Elektrische Griddleplatten Instrucciones de uso Fry top a el ctricos Fig Abb 18 19 Sostituzione delle resistenze Changement du R sistances Substituting the Element...

Страница 6: ...Pag 7 79 Fig Abb 21 22 23 24 Accoppiamento apparecchiature Couplage des appareils Joining appliances Befestigung der Ger te Acoplamiento de los aparatos...

Страница 7: ...0 552 0 740 14 UNI ISO 7 1 R x 2855081 1 module Fry top gas compartment 800x700x845 14 A 1 104 1 481 28 UNI ISO 7 1 R x 2855071 module Fry top gas compartment 400x700x845 7 A 0 552 0 740 14 UNI ISO 7...

Страница 8: ...CAT II2L3B P Gas type Nominal capacity kW Reduced capacity kW Diameter of main injectors 1 100 mm By Pass diameter 1 100 mm Pilot injectors N Air regulation x mm FRY TOP BURNER module Liquid gas LPG 7...

Страница 9: ...be used by trained personnel and for the use for which it was designed Due to the nature of the appliance the temperatures required for cooking may cause various areas of the panelling as well as kit...

Страница 10: ...tic Compatibility EMC 2006 42 EC Machinery directive 2011 65 CE Rohs 2009 42 CE Gas Appliances And the particular reference norms Declaration of compliance The manufacturer declares that the appliance...

Страница 11: ...may be installed as a single unit or together with others In both cases if it is installed near a wall of inflammable material a minimum distance of 100mm from the side and back walls must be observe...

Страница 12: ...ected to a reliably efficient chimney otherwise directly outside fig 7 8 9 pag 4 If this is not possible the use of an extractor fan connected directly to the external environment with a capacity no l...

Страница 13: ...ff cock for rapid interruption of the gas supply placed in an easily accessible position in such a way as to make it possible to turn off the gas supply when the appliance is not being used When the c...

Страница 14: ...emove the pipe of the gauge and put back the screws correctly into the pressure outlet The pressure valve must be within the minimum and maximum values shown below These gases belong to II2HS3B P cate...

Страница 15: ...ining plate 4 on the raised part of the unit tops and fix the M6 screws with an Allen key 6 supplied with the provided kit Once the joining plate 4 has been fixed to the appliances fine adjustment of...

Страница 16: ...ten it well Put back the control panel the drip pan and the knobs Substituting the pilot burner nozzle fig 15 pag 5 To substitute the nozzle of the pilot burner first of all the knobs 1 must be remove...

Страница 17: ...plug is well fixed and connected Check that the igniter plug is intact Check that the igniter cable is intact Check that the piezoelectric igniter is intact and functions correctly Check the gas valv...

Страница 18: ...ion of the glazed finish would be preferable After washing dry the appliance with a soft cloth When cleaning abrasive powders of any type chlorine based detergents and bleach should all be avoided Als...

Страница 19: ...hen necessary to unscrew the fitting of the thermocouple on the cock and the one on the pilot unit then substitute the part Elements fig 12 18 19 pag 5 6 To substitute the elements firstly it is neces...

Страница 20: ...ing to the reuse recycling and enhancement of electrical or electronic devices and protecting the environment and health Abusive product disposal is punishable by law in accordance with current legisl...