INSTALLATION

 

Preliminary operations 

Remove the appliance from the packaging, ensure that it is intact and, if in doubt, do not use it but 
contact professionally qualified personnel. The packaging materials are compliant with environmental 
safety  regulations.  They  can  be  stored  without  risk,  or  else  should  be  disposed  of  in  accordance  with 
current national regulations, particularly those regarding the nylon bag and the polystyrene. 
After verifying that the appliance is in good conditions, the protective film may be removed. Clean 
the external parts of the appliance carefully with warm water and detergent, using a cloth to remove 
all remaining residues and then dry it with a soft cloth. If there are still traces of glue, these can be 
removed using a suitable solvent (e.g. acetone). Under no circumstances should abrasive substances 
be used. After the installation the appliance should be levelled by lowering or raising the adjustable 
legs. 

Gas Connection 

Before connecting the appliance, it is necessary to check that the type of gas available corresponds 
to  the  type  of  gas  the  appliance  has  been  set  for.  In  the  event  that  they  do  not  correspond,  it  is 
necessary  to  proceed  as  described  in  the  paragraph  “Functioning  with  gas  different  from  the 
setting”
.  The  connection  to  the  threaded  coupling,  having  a  diameter  of    ½  inch,  situated  on  the 
bottom  of  the  appliance,  may  be  fixed  or  mobile  using  a  compliant  rapid  pipe  fitting.  If  flexible 
piping  is  used,  this  must  be  in  stainless  steel  and  compliant  with  the  norm.  All  the  seals  on  the 
junction threads must be in guaranteed materials certified for use with gas. Before the installation of 
each single appliance it is necessary to install a cutoff cock for rapid interruption of the gas supply, 
placed in an easily accessible position in such a way as to make it possible to turn off the gas supply 
when the appliance is not being used. When the connection has been completed, the tightness must 
be checked by using a leak-finder spray.  

Electric connection 

Before  connecting  the  appliance,  it  is  necessary  to  check  that  the  voltage  of  the  power  supply 
available  corresponds  to  the  voltage  the  appliance  has  been  set  for.  In  the  event  that  they  do  not 
correspond,  it  is  necessary  to  modify  the  connection  as  shown  in  the  electric  diagram,  if  voltage 
change is provided for. The terminal blocks are situated behind the instrument board and they can 
be removed unscrewing the 2 screws that fix the support and pulling out the same and the terminal 
blocks.Furthermore, the efficiency of the earth connection must be checked, and also that the earth 
conductor on the connecting side is longer than the other conductors, and that the connecting cable 
has a wire bunch adequate for the power absorbed by the appliance and is at least type H05 RN-F. 
As  in  international  provisions,  before  installing  the  appliance  a  unipolar  device  must  be 
installed  with  a  contacts  opening  of  at  least  3mm  which  must  not  interrupt  the  YELLOW-
GREEN earth wire.
 The device must be installed near the appliance, it must be approved and have 
adequate capacity for the absorption of the appliance (see technical features). 
The appliance must be connected to the EQUIPOTENZIALE system. The connector is situated near 
the end of the electric cable and is identified by a label with the symbol shown on figure 10 (pag. 5). 
When using a safety switch for fault currents, the following should be observed:  

-

 

According to current legislation, these kind of appliances can have a leakage current of 1mA 
per kW of rated power input with no maximum. It should also be noted that all fault current 

Содержание 70 Series

Страница 1: ...Pag 22 50 GAS FRY TOPS ELECTRIC FRY TOPS SERIES 70 INSTALLATION USE AND MAINTENANCE 286506 286508 2855051 2855071 286507 286509 2855061 2855081 GB UK...

Страница 2: ...5081 G gas gaz Fig Abb 1 Dimensioni Dimensions Floor space dimensions Raumbedarfsmasse Espacio m ximo necesario 285606 286508 286507 286509 Fig Abb 4 Dimensioni Dimensions Floor space dimensions Raumb...

Страница 3: ...50 20 20 DE ART II2H3B P p mbar 50 50 20 AT CH CZ SK N II2H3B P p mbar 28 30 28 30 20 FI LT BG kW B II2H3B P p mbar 28 30 28 30 20 NO SK RO Qn m h C II2H3B P p mbar 28 30 28 30 20 EE SI HR TR kg h D...

Страница 4: ...ruciatore Changement du gicleur du br leur Substituting the burner nozzle Austausch der Hauptbrennerd se Cambio boquilla quemador Fig Abb 13 Regolazione dell aria primaria bruciatore R glage de l air...

Страница 5: ...nstruction for use Electric fry tops Elektrische Griddleplatten Instrucciones de uso Fry top a el ctricos Fig Abb 18 19 Sostituzione delle resistenze Changement du R sistances Substituting the Element...

Страница 6: ...Pag 7 79 Fig Abb 21 22 23 24 Accoppiamento apparecchiature Couplage des appareils Joining appliances Befestigung der Ger te Acoplamiento de los aparatos...

Страница 7: ...0 552 0 740 14 UNI ISO 7 1 R x 2855081 1 module Fry top gas compartment 800x700x845 14 A 1 104 1 481 28 UNI ISO 7 1 R x 2855071 module Fry top gas compartment 400x700x845 7 A 0 552 0 740 14 UNI ISO 7...

Страница 8: ...CAT II2L3B P Gas type Nominal capacity kW Reduced capacity kW Diameter of main injectors 1 100 mm By Pass diameter 1 100 mm Pilot injectors N Air regulation x mm FRY TOP BURNER module Liquid gas LPG 7...

Страница 9: ...be used by trained personnel and for the use for which it was designed Due to the nature of the appliance the temperatures required for cooking may cause various areas of the panelling as well as kit...

Страница 10: ...tic Compatibility EMC 2006 42 EC Machinery directive 2011 65 CE Rohs 2009 42 CE Gas Appliances And the particular reference norms Declaration of compliance The manufacturer declares that the appliance...

Страница 11: ...may be installed as a single unit or together with others In both cases if it is installed near a wall of inflammable material a minimum distance of 100mm from the side and back walls must be observe...

Страница 12: ...ected to a reliably efficient chimney otherwise directly outside fig 7 8 9 pag 4 If this is not possible the use of an extractor fan connected directly to the external environment with a capacity no l...

Страница 13: ...ff cock for rapid interruption of the gas supply placed in an easily accessible position in such a way as to make it possible to turn off the gas supply when the appliance is not being used When the c...

Страница 14: ...emove the pipe of the gauge and put back the screws correctly into the pressure outlet The pressure valve must be within the minimum and maximum values shown below These gases belong to II2HS3B P cate...

Страница 15: ...ining plate 4 on the raised part of the unit tops and fix the M6 screws with an Allen key 6 supplied with the provided kit Once the joining plate 4 has been fixed to the appliances fine adjustment of...

Страница 16: ...ten it well Put back the control panel the drip pan and the knobs Substituting the pilot burner nozzle fig 15 pag 5 To substitute the nozzle of the pilot burner first of all the knobs 1 must be remove...

Страница 17: ...plug is well fixed and connected Check that the igniter plug is intact Check that the igniter cable is intact Check that the piezoelectric igniter is intact and functions correctly Check the gas valv...

Страница 18: ...ion of the glazed finish would be preferable After washing dry the appliance with a soft cloth When cleaning abrasive powders of any type chlorine based detergents and bleach should all be avoided Als...

Страница 19: ...hen necessary to unscrew the fitting of the thermocouple on the cock and the one on the pilot unit then substitute the part Elements fig 12 18 19 pag 5 6 To substitute the elements firstly it is neces...

Страница 20: ...ing to the reuse recycling and enhancement of electrical or electronic devices and protecting the environment and health Abusive product disposal is punishable by law in accordance with current legisl...

Отзывы: