Enabling Periodic Beacon
Factory Default: 10 minutes
This option generates a beacon that will be sent on every programmed channel. The interval in minutes determines
how often the beacon(s) will be sent.
Select “Periodic Beacon” from the “Operational Menu”.
Use the ‘UP’ and ‘DOWN’ arrow keys to select the interval in minutes that the beacons will be sent. To disable the
periodic beacon select “00 Minute(s)”. The maximum beacon interval is sixty minutes, the minimum is one minute.
Press ‘END’ to confirm selection.
Selecting the Charging Method
Factory Default: Time Charging
In addition to charging the client for the length of time on-line, a charge pulse can be setup to be sent from the
Telephone exchange at a unit time interval as determined by the telephone exchange charging rates. A unit interval
for example may be every 30 seconds for a long distant phone call. This is available to out going calls only.
The available pulse detection types are 50Hz, 12kHz and 16kHz. These may not be available in some countries.
A combination is not possible.
Select “Charging Method” from the “Operational Menu”.
Use the ‘UP’ and ‘DOWN’ arrow keys to select the charging type. Press ‘END’ to confirm selection.
Enabling the Printer
Factory Default: Yes, Enabled
Enabling this will generate printed information out of the printer port.
Select “Printer Enable” from the “Operational Menu”.