BARRETT 2030 HF SSB TRANSCEIVER
Selcall Pre-amble Length Setting
The Selcall pre-amble length can be set between 1 and 10 seconds depending on
how many channels are used in the scan table being used. Allow 500 mS for each
Selcall channel to be scanned plus one second, E.g. to scan 8 Selcall channels:-
500 mS x 8 + 1 sec. = 5 seconds.
Use
the
Scroll keys
to select the Selcall pre-amble length
required (example “5 seconds”):-
When the setting required is selected press the
key