PAGE 50 

SPECIFICATIONS 

 

 

Relay Failure - when the contact position does not 
match the coil setting. 

 

 

Roaming - indicates abnormal phone behavior since 
the Link is presumably installed at a fixed location. 

 

 

Unknown Cell Status - failure to obtain network 
connection so there can be no callout actions. 

 

 

Low RSSI - insufficient signal strength to reliably 
operate the cell phone. 

APN server: 

Access Point Name server.  Rogers access point to 
obtain an IP address and establish connection to the 
internet.  For Rogers in Canada the default is "vpn.com". 

APN user: 

Access Point Name user.   For Rogers in Canada the 
default is "wapuser1". 

APN password:  Access Point Name password.  For Rogers in Canada 

the default is "wap". 

SMTP server: 

Rogers wireless email server.  For Rogers in Canada the 
default is "smtp.rogerswirelessdata.com". 

APN SMTP  
server:   

Required to use the SMTP server.  For Rogers in Canada 
the default is "internet.com". 

 
Account address: This will appear in the "From:" portion of an outgoing 

email.  It is the address where the outgoing email 
containing the current IP address of the wireless port is 
sent for a data transfer session. 

 

example: From: [email protected] 

11.2.8 W2 module 

Digital Inputs: 

8 total, ground closure operation 

 

Internally pulled up to +5 VDC 

 

1 M ohm input impedance 
Programmable as standard digital, watchdog, pulse 
width, totalizer or accumulator types 

Relay Outputs: 

4 total, form C, 2A at 30 VDC 

 

Programmable as on/off or timed 
Latching coils, can be programmed to maintain previous 
state on power-up  

Antenna port: 

50 ohms, SMA female 

Содержание ProTalk LINK

Страница 1: ...215 7710 5th Street SE Calgary Alberta Canada T2H 2L9 Phone 403 255 9544 Fax 403 259 2343 www barnett engg com E mail sales barnett engg com June 2016 Rev 3 02 Operating Manual Hardware...

Страница 2: ......

Страница 3: ...2 3 M1 INSTALLATION 6 4 A1 INSTALLATION 10 5 D1 INSTALLATION 13 6 P1 INSTALLATION 16 7 P2 INSTALLATION 21 8 T1 INSTALLATION 24 9 W1 INSTALLATION 28 10 W2 INSTALLATION 33 11 W3 INSTALLATION 37 12 SPEC...

Страница 4: ......

Страница 5: ...ndancy is required For low density alarm counts the input output capabilities of a communication module will be adequate When the alarm count exceeds this capacity one or more of the discrete I O modu...

Страница 6: ...required communications and I O functionality The first expander module is plugged into the Main module then the next expander into the first expander and so on The ProTalk Link System accepts a maxi...

Страница 7: ...he expanders from 1 upwards as they are connected together If there is a PLC module it is recommended that any I O or communications modules be addressed starting from 1 then the PLC module given the...

Страница 8: ...ERVIEW Figure 3 Module Dimensions Figure 3 shows the dimensions for both Main and expander modules The Main module does not have the connector on the bottom nor an address switch it is always address...

Страница 9: ...INSTALLATION OVERVIEW PAGE 5 Figure 4 ProTalk LINK in a NEMA enclosure Figure 4 shows the ProTalk LINK with three expanders when it is mounted in a NEMA enclosure ProTalk ProTalk ProTalk ProTalk...

Страница 10: ...quires a power supply voltage of 10 30 VDC 2 8A Max The power supply used should be a safety approved Class 2 power supply source current limited using a 3A in line slow blow fuse Total system power w...

Страница 11: ...pment is to be notified of system status conditions the output relays can be used Each of the two relays can be programmed to indicate one of these status conditions New alarm exists Any alarm exists...

Страница 12: ...enter control codes Limited programming functionality is available through the telset Do not plug a telephone line into this port Figure 7 M1 Module Connections Figure 8 M1 DB9 to PC Programming Cable...

Страница 13: ...idle 2 Alarm Supply Power Fail System Major Minor Flashing Red with an unacknowledged alarm Solid Red with an acknowledged alarm Off when idle 3 Output Two one for each output Red when active Off oth...

Страница 14: ...t flow must be such that the current source enters the terminal and exits from the terminal The input can be either at the top of the loop with the terminal connected to the loop excitation voltage or...

Страница 15: ...oltage error can be generated This alarm can be selected as either major or minor and is reported for the module and not for a specific input A voltage input can withstand a constant voltage of up to...

Страница 16: ...This indicator times out after 400 msec Over Flashing Red when a voltage input is over range Off otherwise Loop Flashing Red when a current loop input is open Off otherwise 2 Alarm Sixteen one for eac...

Страница 17: ...ways associated with a specific digital input Clear inputs 1 through 4 work with digital inputs 1 through 4 respectively totalizers or accumulators derived from other inputs can be reset using DTMF on...

Страница 18: ...15 D1 Input Circuit Indicators The indicators are grouped into 2 sections 1 Status Run Flashing Red during startup before a database is received from the main module Green during normal operations RX...

Страница 19: ...le 2 Alarm Sixteen one for each input Flashing Red when the associated input is in the alarm state Yellow when there is an error with an input connection Red when the associated input is in the alarm...

Страница 20: ...g the status of the Link system regardless of which port is selected for PLC communications Protocols used by the module are Modbus slave Modbus master Modbus TCP IP slave Modbus TCP IP master Allen B...

Страница 21: ...rations Green on receipt of valid message from the main module Yellow if the message from the main module has a checksum error This indicator times out after 400 msec 2 Comm Port Green if the Ethernet...

Страница 22: ...2x host has a problem and will not communicate 3x remote node host is missing disconnected or shut down 4x host could not complete function due to hardware fault 5x addressing problem or memory protec...

Страница 23: ...changed since the start of the command D9 data or file is too large DA transaction size plus word address is too large DB access denied improper privilege DC condition cannot be generated resource is...

Страница 24: ...PAGE 20 P1 INSTALLATION FD not enough characters FE CRC error FF no response...

Страница 25: ...ail Ethernet port is available for monitoring the status of the Link system or transmitting emails Protocols used by the module for PLC communications are Modbus RTU slave Modbus RTU master Modbus TCP...

Страница 26: ...n the configuration only one protocol can be assigned to this port RS485 The RS485 port performs the same function as the RS232 port The protocol used through this port is selected in the configuratio...

Страница 27: ...d Red no response Solid Green valid response Solid Yellow invalid response Modbus RTU Slave Solid Red no response Solid Green valid response Solid Yellow invalid message Modbus AB DFI Master Solid Red...

Страница 28: ...alizer Accumulator There are also 4 relay outputs that can be used for remote control these relays are controlled by incoming DTMF codes Connectors Refer to Figure 21 for details of the connector pino...

Страница 29: ...d The T1 module can be called through this port by the Link configuration application allowing configuration settings to be remotely changed using the PC A limited amount of programming can also be do...

Страница 30: ...n when a tone is being received Red when a tone is being transmitted Off when idle Hook Red when ringing on an incoming call Green when off hook Off when idle Modem Green when modem is waiting for a c...

Страница 31: ...T1 INSTALLATION PAGE 27 3 Output Four one for each output Red when the relay is in the on state Yellow if the relay has failed Off otherwise...

Страница 32: ...anced callout requirements the module can be configured to send email messages containing the alarm information A limited amount of programming can also be done using a Touch Tone set locally or by ca...

Страница 33: ...y DTMF codes Indoor Antenna Indoor Antenna Installation For the W1 Link module to successfully make cellular calls there must be adequate signal strength at its antenna port The flex antenna supplied...

Страница 34: ...dem is enabled Yellow when the modem has a data connection Red when disconnecting Off when disconnected RSSI Flashing Red when RSSI is 0 very poor Red when RSSI is between 1 and 3 poor Yellow when RSS...

Страница 35: ...unit Remove the four black screws holding the lid on Remove the two silver screws on the top of the unit and separate the lid from the base Note there is an aluminum shim around the DB15 connector th...

Страница 36: ...PAGE 32 W1 INSTALLATION Figure 27 Rear View of Modem Module...

Страница 37: ...ted amount of programming can also be done using a safety approved Touch Tone telephone locally or by calling into the module This module can be used to transfer a database to the ProTalk Link if the...

Страница 38: ...DTMF codes Antenna Connection of the external antenna is at the SMA female coax connector Indoor Antenna Installation For the W2 Link module to successfully make cellular calls there must be adequate...

Страница 39: ...ta connection Red when disconnecting Off when disconnected RSSI Flashing Red when RSSI is 0 very poor Red when RSSI is between 1 and 3 poor Yellow when RSSI is 4 or 5 marginal Green when RSSI is 6 or...

Страница 40: ...N Mobile Directory Number must be obtained from your carrier and programmed into the unit For programming instructions refer to Wireless Module Programming in the Handset Programming section or to the...

Страница 41: ...e can be configured to send email and text messages containing the alarm information and can also receive text messages containing control codes A limited amount of programming can also be done using...

Страница 42: ...outputs that are operated by DTMF codes Indoor Antenna Indoor Antenna Installation For the W3 Link module to successfully make cellular calls there must be adequate signal strength at its antenna por...

Страница 43: ...therwise Modem Green when modem is enabled Yellow when the modem has a data connection Red when disconnecting Off when disconnected RSSI Flashing Red when RSSI is 0 very poor Red when RSSI is between...

Страница 44: ...located on the front of the case It is important to observe proper electrostatic grounding precautions and to disconnect power prior to performing this procedure What you ll need Fine point object eg...

Страница 45: ...panel installation Environmental 40 C to 60 C 95 humidity non condensing Power 10 VDC to 30 VDC Expander output DB15 female top of case to additional expander modules Expander input DB15 male bottom o...

Страница 46: ...DB9 port 1 disables the DB9 when connected to a PC Telset program port RJ11 Connects to a DTMF telset for voice programming and limited configuration programming Programmable Features Site Name This...

Страница 47: ...hen annunciated Minor Alarm This system alarm is the product of ORing all of the minor alarms that can be set in each module If enabled it produces the message Minor alarm when annunciated System Alar...

Страница 48: ...ule Digital Inputs 16 total Impedance 250k ohms Maximum voltage 30 VDC Minimum voltage 5 VDC Clear Inputs 4 total function as clear controls for digital inputs that are programmed as a totalizer or ac...

Страница 49: ...unications Ports RS232 or RS485 selectable Stop bit 1 Parity even odd or none Checksum CRC or BCC A B modes CRC Modbus modes Baud rate 300 1200 2400 4800 9600 19200 38400 57600 115200 Ethernet IP addr...

Страница 50: ...ting with 1 in the first location in block 0 then in ascending order through the 32 blocks 12 2 5 P2 Module Communications Ports RS232 DTE DB9 RS485 2 wire terminal block Ethernet Local PLC Network 10...

Страница 51: ...strator Block Addressing Protocol Each block consisting of 16 points is assigned a protocol and a PLC to communicate with The protocol selected can be any of the always available Ethernet protocols or...

Страница 52: ...assembly the block of alarms is located 12 2 6 T1 module Digital Inputs 8 total ground closure operation Internally pulled up to 5 VDC 1 M ohm input impedance Programmable as standard digital watchdog...

Страница 53: ...will be the level that the audio signal for that type is transmitted at For the RX setting it is the level of the signal coming from the receiver TX Tone 2 5 Tone paging alert tone TX DTMF DTMF signal...

Страница 54: ...Canada the default is wap SMTP server Rogers wireless email server For Rogers in Canada the default is smtp rogerswirelessdata com APN SMTP server Required to use the SMTP server For Rogers in Canada...

Страница 55: ...total form C 2A at 30 VDC Programmable as on off or timed Latching coils can be programmed to maintain previous state on power up Antenna port 50 ohms SMA female SIM Card Mini SIM 25 00mm L x 15 00mm...

Страница 56: ...PAGE 52 SPECIFICATIONS server Required to use the SMTP server For Rogers in Canada the default is internet com...

Страница 57: ...the 8 groups Note that the Group that the alarm is assigned to must also be enabled for alarm reporting DTMF TX Code If one or more DTMF digits are entered in Alarm On Code they will be transmitted w...

Страница 58: ...le 66535 minutes maximum Can be configured to measure either polarity at the input 4 Totalizer counts input events 5 counting scales are available to place the decimal point XXXXX XXXX Y XXX YY XX YYY...

Страница 59: ...nd on which module that the analog input is in Details on what is allowed for each module type are shown in the specification for that module Minimum The two values in the minimum setting controls are...

Страница 60: ...annunciated The first selection is a multiplier e g thousand or million the second selection is a measurement unit e g degrees or PSI and the third selection is a qualifier e g per second or per hour...

Страница 61: ...ols shown below may not be changeable Details on what settings can be changed are shown in the specification for each module Output Type Sets whether the relay is On Off or Timed Action On Determines...

Страница 62: ...e coil to 1 Can be a string of 1 to 7 digits Off Code The DTMF code that sets the coil to 0 Can be a string of 1 to 7 digits 12 4 5 PLC Analog alarm types Function Sets the type of functions that the...

Страница 63: ...same 3 unit controls that are provided for analog alarms to supply the descriptive phrase that is appended to the reading See section 10 2 3 3 Commwatch Analog commwatch alarms operate in a similar fa...

Страница 64: ...andset programming is always available locally access for remote programming depends on the Security Level setting Level 1 The call will be answered with a message containing the Site ID any Groups th...

Страница 65: ...a summary below 1 Voices page 50 2 Directories page 51 3 Hardware Configuration page 53 5 General Configuration page 62 6 Group Configuration page 64 7 not used 8 Reset Database page 66 9 Module Stat...

Страница 66: ...Block 31 99 Erase all voices Exit to Main Menu Exit to Main Menu Playback or Record Voices Link Site is Ajax Compressor Station or Block 1 input output register coil 1 is Low Temperature You 2 Record...

Страница 67: ...ry Line Refer to the command list that follows for the available directory entries Link Directory 1 Line 1 is DIAL 2559544 VOICE You 2 Edit current line 3 Erase current line 4 Insert line Next line Ex...

Страница 68: ...the command it is following 0X DIAL X is the telephone number 1 RADIO 2X WAIT X is the time in seconds 1 to 255 3 ALERT 4X 2 TONE X is the paging frequencies with an assumed decimal before the last d...

Страница 69: ...n Note The switch uses the 1 Address 1 letters A to F to represent the numbers 10 to 15 15 Address 15 Exit to Main Menu Next module Address 1 Link Module Zero is M1 You Exit to Hardware Configuration...

Страница 70: ...k Access Code is You X Enter a new DTMF code Exit to Main Menu Next setting Link Shift Count is You X Enter new value 1 to 8 Exit to Main Menu Next setting Link Shift Code is You X Enter a new DTMF co...

Страница 71: ...DSET PROGRAMMING PAGE 67 Link Primary Phone Modem Code is You X Enter new DTMF code Exit to Main Menu Next setting Link Backup Phone Modem Code is You X Enter new DTMF code Exit to Main Menu Next sett...

Страница 72: ...nterrogate Code is You X Enter a new DTMF code Exit to Main Menu Next setting Link Short Timer is You X Enter new value 1 to 255 min Exit to Main Menu Next setting Link Short Cycles is You X Enter new...

Страница 73: ...k On Shift One Use Directory You X Enter new value 1 to 32 Exit to Main Menu Next setting repeats for the number set in Shift Count Link On Shift Eight Use Directory You X Enter new value 1 to 32 Exit...

Страница 74: ...PAGE 70 HANDSET PROGRAMMING 8 Reset Database Link Enter Empty Code You 31 Link Program is Empty...

Страница 75: ...esent the numbers 10 to 15 15 Address 15 Exit to Main Menu Next module Address 1 Link Module One is module type or empty Status if available Link Signal Strength is Module Status M1 none A1 none D1 no...

Страница 76: ...ssigned to the installed SIM module The first device programmed will be the one assigned as the PRIMARY PHONE device see General Configuration After programming this device an attempt will be made to...

Страница 77: ...HANDSET PROGRAMMING PAGE 73...

Страница 78: ...NG 99 Local Handset Callout Link beep You X Enter the phone number you want to call If the system has two callout modules T1 W1 W2 and W3 the call will be placed through the one that is set as primary...

Страница 79: ...You Exit to Main Menu You Exit to Main Menu Link Module M0 is speaks serial number You Exit to Query Version You Next Link Hardware version is You Exit to Query Version You Next Link Firmware version...

Страница 80: ...ment or refund the purchase price at Barnett Engineering Ltd s option after return of such equipment by buyer to Barnett Engineering Ltd Shipment to Barnett Engineering Ltd s facility shall be borne o...

Страница 81: ...armful interference and 2 this device must accept any interference received including interference that may cause undesired operation Warning This equipment generates uses and can radiate radio freque...