PAGE 16
P1 INSTALLATION
6. P1 INSTALLATION
Figure 16 P1 Module - Front Panel
The P1 module provides connectivity between the Link system and a PLC.
Communications between the P1 module and the PLC can be done using
one of the available ports: the RS232 serial port, the RS485 serial port or,
for Modbus systems, the Ethernet port. Only one of the three ports can be
assigned for PLC communications at a time. The Ethernet port is
available for monitoring the status of the Link system regardless of which
port is selected for PLC communications.
Protocols used by the module are:
Modbus slave
Modbus master
Modbus TCP/IP slave
Modbus TCP/IP master
Allen-Bradley DF1 Point-to-Point PLC5 master
Allen-Bradley DF1 Point-to-Point SLC-500 master.
Figure 17 P1 Module - Connectors
Connectors
RS232
This DTE RS232 serial port connected to the communications port of
the PLC. Either this port or the RS485 port is selected in the
configuration; both do not operate at the same time.
10
RUN
STATUS
POR
T
RX
/TX
RX
/TX
COMM
0
1
3
2
4
7
5
6
8
9
ALARM BLOCK
(A)-
LINK
ACT
15
ETHERNET
11 12
14
13
RS232
(B)+
GN
D
B1285-P1
RS485
Содержание ProTalk LINK
Страница 2: ......
Страница 4: ......
Страница 24: ...PAGE 20 P1 INSTALLATION FD not enough characters FE CRC error FF no response...
Страница 36: ...PAGE 32 W1 INSTALLATION Figure 27 Rear View of Modem Module...
Страница 56: ...PAGE 52 SPECIFICATIONS server Required to use the SMTP server For Rogers in Canada the default is internet com...
Страница 74: ...PAGE 70 HANDSET PROGRAMMING 8 Reset Database Link Enter Empty Code You 31 Link Program is Empty...
Страница 77: ...HANDSET PROGRAMMING PAGE 73...