SPECIFICATIONS
PAGE 49
No dial tone - when there is no dial tone because the
telco line is not connected or the port has been
damaged
PTT Warmup:
The interval between when the PTT signal is asserted to
activate the radio transmitter and the beginning of the
message.
Can be 0 to 65530 msec. in 10 msec. steps.
COS Detect:
The Carrier Operated Switch (COS) is a signal that is
generated by the radio receiver to indicate that it is busy.
Disable - not used for busy channel detect
Busy Hi - high level when the receiver is active
Busy Lo - Low level when the receiver is active
Audio Levels:
Variable from 0 dBm to -20 dBm.
For the TX controls this setting will be the level that the
audio signal for that type is transmitted at. For the RX
setting it is the level of the signal coming from the
receiver.
TX Tone
2/5 Tone paging, alert tone
TX DTMF
DTMF signaling
TX Voice
Voice messages
Receive
All audio
Rings Before
Answer:
1 to 9 or never
This sets the number of rings that must be detected
before the line is answered
12.2.7 W1 Module
Digital Inputs:
8 total, ground closure operation
Internally pulled up to +5 VDC
1 M ohm input impedance
Programmable as standard digital, watchdog, pulse
width, totalizer or accumulator types
Relay Outputs:
4 total, form C, 2A at 30 VDC
Programmable as on/off or timed
Latching coils, can be programmed to maintain previous
state on power-up
Antenna port:
50 ohms, SMA female
Programmable Features
Major/Minor
Alarms:
Each of these can be either a major or minor alarm:
Содержание ProTalk LINK
Страница 2: ......
Страница 4: ......
Страница 24: ...PAGE 20 P1 INSTALLATION FD not enough characters FE CRC error FF no response...
Страница 36: ...PAGE 32 W1 INSTALLATION Figure 27 Rear View of Modem Module...
Страница 56: ...PAGE 52 SPECIFICATIONS server Required to use the SMTP server For Rogers in Canada the default is internet com...
Страница 74: ...PAGE 70 HANDSET PROGRAMMING 8 Reset Database Link Enter Empty Code You 31 Link Program is Empty...
Страница 77: ...HANDSET PROGRAMMING PAGE 73...