20

PARTS KITS

Seal Repair Kits: 
 

Single Seal .......... ..P/N - 107276  

(

†) 28, 36

 

Double Seal ...........P/N - 107277  

(

♦) 27, 28, 32, 36

Seal Tool Kit  ....................P/N - 107271
Pressure Gauge Kit  ........P/N - 085343

PARTS LIST

ITEM QTY.  PART 

NO.   

DESCRIPTION

1 1 103604   

Volute

003217 

 

Pipe Plug 

 

All double seal (Std), .25” NPT, ZP

 

039383 

 

Moisture Sensor Probes 

(Optional) for moisture sensor

084532 

 

Seal Plate 

 

All single seal

 

 

084906 

 

Seal Plate 

 

All double seal

6 1 105196   

Motor 

Housing 

  (Std)

 

 

105196HA 

 

(Optional) for moisture and temp. sensors

7 1  

 

Motor:

  030369BS 

 

4SE914L

  030369BD 

 

4SE914DS

  030370BS 

 

4SE924L

  030370BD 

 

4SE924DS

  071352BS 

 

4SE994L, 

4SE944L

  071352BD 

 

4SE994DS, 

4SE944DS

  092854BS 

 

4SE954L

  092854BD 

 

4SE954DS

  085472BS 

 

4SE1474L

  085472BD 

 

4SE1474DS

  029792BS 

 

4SE1924L

  029792BD 

 

4SE1924DS

 

 

071354BS 

 

4SE1494L, 4SE1444L, 4SE1994L, 4SE1944L

 

 

071354BD 

 

4SE1494DS, 4SE1444DS, 4SE1994DS, 4SE1944DS

  092855BS 

 

4SE1454L, 

4SE1954L

  092855BD 

 

4SE1454DS, 

4SE1954DS

96oz 

029034 

 

Oil 

 

 

All single seal

 

120oz 

029034 

 

Oil 

 

 

All double seal (Includes 24oz. in Seal Chamber)

9 1 034964  * 

Capacitor    (30MFD) 

Phase

10 

039858 

 

Capacitor Bracket  1 Phase

11 

1-129-1 

 

Hex. Hd. Cap Screw 

(Std), 5/16-18 x .75” Lg., Stainless

 

1-129-1 

 

Hex. Hd. Cap Screw 

(Optional) for moisture and temp. sensors

12 

026322 

 

Lockwasher 

 

(Std), 5/16, Stainless

 

10 

026322 

 

Lockwasher 

 

(Optional) for moisture and temp. sensors

13 1  103503   

Handle

16 

See Table 2 

 

Power Cable Set

16a 

103582 

 

Compression Flange 

Included with cable set

19 1  105197   

Snap 

Ring   

(Std)

 

105197 

 

Snap Ring 

 

(Optional) for moisture and temp. sensors

20 1  2-31051-224 

 

O-ring 

 

 

(Std)

 

2-31051-224 

 

O-ring 

 

 

(Optional )for moisture and temp. sensors

21 

103584 

 

Terminal Block 

1 Phase

 

103583 

 

Terminal Block 

3 Phase

22 1  105111   

Ground 

Wire 

Assembly 

(Std)

 

105111 

 

Ground Wire Assembly 

(Optional) for moisture and temp. sensors

23 

016660 

 

Screw 

#8-32 x .375” Lg.

24 1  085326   

Retaining 

Ring

25 1  017414   

Bearing

26 

1-135-1 

 

Cap Screw 

All single seal, 5/16-18 x 1.75” Lg., Stainless

 

1-168-1 

 

Cap Screw 

All double seal, 5/16-18 x 3.50” Lg., Stainless

27 

027269 

♦ 

Square Ring 

All single seal

 

027269 

 

Square Ring 

All double seal

* Units with build code date (see section G-4) before -0901 may 
use capacitor part number, 070963 or the 034964 part number.

Содержание 4SE-DS series

Страница 1: ...product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua O...

Страница 2: ...7 DOUBLE SEAL CROSS SECTION Fig 17 18 DOUBLE SEAL EXPLODED VIEW Fig 18 19 PARTS LIST 20 22 RETURNED GOODS POLICY 23 WARRANTY 24 START UP REPORT 25 26 WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT...

Страница 3: ...insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Страница 4: ...l Filled Squirrel Cage Induction Insulation Class B SINGLE PHASE Permanent Split Capacitor PSC Includes overload protection in motor THREE PHASE 200 240 480 is Tri voltage motor 600V Requires overload...

Страница 5: ...out vanes on Back side Dynamically balanced ISO G6 3 Material Cast Iron ASTM A 48 Class 30 SHAFT 416 Stainless Steel SQUARE RINGS Buna N HARDWARE 300 Series Stainless Steel PAINT Air dry enamel top co...

Страница 6: ...n or basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage ef uent or other nonexplosive or noncorrosive wastewater and shall NOT be installed in locations...

Страница 7: ...ntinuous Amperes Inrush Amperes 110 120 3 00 30 0 220 240 1 50 15 0 440 480 0 75 7 5 600 0 60 6 0 C 4 3 Moisture Sensors DS Models Optional A normally open N O detector is installed in the pump seal c...

Страница 8: ...1 13 7 15 4 14 4 SOW 0 570 14 5 5 49 6 28 4SE1944DS 1 9 480 3 60 1750 B 2 5 7 7 14 4 SOW 0 570 14 5 21 96 24 51 4SE1954DS 1 9 600 3 60 1750 C 1 9 7 2 14 4 SOW 0 570 14 5 34 36 35 60 Winding Resistanc...

Страница 9: ...e gauge assembly and tighten into hole see Figure 3 Pressurize motor housing to 10 P S I Use soap solution around the sealed areas above the oil level and inspect joints for air bubbles For sealed are...

Страница 10: ...ation disassemble volute and impeller as outlined in paragraph F 2 1 If further repair is required remove retaining ring 28d spring 28c and rotating member 28b from shaft see Figures 5 6 Examine all s...

Страница 11: ...tor and Bearing Service F 4 1 Disassembly and Inspection To examine or replace the motor 7 capacitor 9 single phase units controls 56 optional and bearing 25 drain oil from motor as outlined in paragr...

Страница 12: ...ce department Bearings When replacing bearing be careful not to damage the rotor or shaft threads Clean the shaft thoroughly Press bearing 25 on the motor shaft position squarely onto the shaft applyi...

Страница 13: ...ragraph G 2 4 Part description 5 Item part number 6 Quantity required 7 Shipping instructions 8 Billing Instructions G 2 PART NUMBER The part number consists of a six 6 digit number which appears in t...

Страница 14: ...14 FIGURE 13 CONTIUED...

Страница 15: ...Check cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is se...

Страница 16: ...16 FIGURE 15 4SE L Series Single Seal...

Страница 17: ...17 FIGURE 16 4SE L Series Single Seal...

Страница 18: ...18 FIGURE 17 4SE DS Series Double Seal...

Страница 19: ...19 FIGURE 18 4SE DS Series Double Seal...

Страница 20: ...1 034964 Capacitor 30MFD 1 Phase 10 1 039858 Capacitor Bracket 1 Phase 11 4 1 129 1 Hex Hd Cap Screw Std 5 16 18 x 75 Lg Stainless 6 1 129 1 Hex Hd Cap Screw Optional for moisture and temp sensors 12...

Страница 21: ...46TR 4 00 Dia 34 3 005808 Nipple 35 3 003479 Cap 36 1 027344 Gasket 39 1 014270 Pipe Plug 375 NPT ZP 41 A R Loctite242 42 A R Permatex2C 44 1 003217 Pipe Plug All double seal 25 NPT ZP 45 2 5 32 6 Scr...

Страница 22: ...ature Sensor 3 Phase or Moisture Sensor 8 FT 103756A 103741A 103742A 103741A 103740A 15 FT Std 103756 103741 103742 103741 103740 20 FT 103756XA 103741XA 103742XA 103741XA 103740XA 30 FT 103756XC 1037...

Страница 23: ...o Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the e...

Страница 24: ...guarantees in the nature of performance speci cations furnished in addition to the foregoing material and workmanship warranties on a product manufactured by us if any are subject to laboratory tests...

Страница 25: ...m Does impeller turn freely by hand Yes No Condition of equipment Good Fair Poor Condition of cable jacket Good Fair Poor Resistance of cable jacket Good Fair Poor Resistance of cable and pump motor m...

Страница 26: ...ction Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for...

Страница 27: ...CITY STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Syst...

Страница 28: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE...

Отзывы: