6

TROUBLE SHOOTING

CAUTION !

 Always disconnect the pump from the electrical power source before handling.

If the system fails to operate properly, carefully read instructions and perform maintenance recommendations.
If operating problems persist, the following chart may be of assistance in identifying and correcting them:

MATCH “CAUSE” NUMBER WITH CORRELATING “CORRECTION” NUMBER

.

NOTE:

 Not all problems and corrections will apply to each pump model.

PROBLEM

CAUSE

CORRECTION

Pump will not run

1.

 Poor electrical connection, blown fuse, 

tripped breaker or other interruption of power, 
improper power supply.

2.

 Motor or switch inoperative (to isolate 

cause, go to manual operation of pump).

2a.

 Float movement restricted.

2b. Switch will not activate pump or is defec-
tive.

3.

 Insuffi cient liquid level.

1. Check all electrical connections for 
security. Have electrician measure current 
in motor leads, if current is within ±20% 
of locked rotor Amps, impeller is probably 
locked. If current is 0, overload may be 
tripped. Remove power, allow pump to cool, 
then recheck current.
2a. Reposition pump or clean basin as 
required to provide adequate clearance for 
fl oat.
2b. Disconnect level control. Set ohmmeter 
for a low range, such as 100 ohms full scale 
and connect to level control leads. Actuate 
level control manually and check to see that 
ohmmeter shows zero ohms for closed switch 
and full scale for open switch. (Float Switch).
2c. Check winding insulation (Megger Test) 
and winding resistance. If check is outside 
of range, dry and recheck. If still defective, 
replace per service instructions.
3. Make sure liquid level is at least equal to 
suggested turn-on point.
4. Recheck all sizing calculations to 
determine proper pump size.
5. Check discharge line for restrictions, 
including ice if line passes through or into 
cold areas.
6. Remove and examine check valve for 
proper installation and freedom of operation.
7. Open valve.
8. Check cutter for freedom of operation, 
security and condition. Clean cutter and inlet 
of any obstruction.
9. Loosen union slightly to allow trapped air 
to escape.Verify that turn-off level of switch 
is set so that the suction is always fl ooded. 
Clean vent hole.
10. Check rotation. If power supply is three 
phase, reverse any two of three power supply 
leads to ensure proper impeller rotation.
11. Repair fi xtures as required to eliminate 
leakage.
12. Check pump temperature limits & fl uid 
temperature.
13. Replace portion of discharge pipe with 
fl exible connector.
14. Turn to automatic position.
15. Check for leaks around basin inlet and 
outlets.

Pump will not turn off

2a.

 Float movement restricted.

2b.

 Switch will not activate pump or is defec-

tive.

4. 

Excessive infl ow or pump not properly sized 

for application.

9.

 Pump may be airlocked.

14.

 H-O-A switch  on panel is in “HAND” position

Pump hums but does not run

1.

 Incorrect voltage

8.

 Impeller jammed or loose on shaft, worn or 

damaged, impeller cavity or inlet plugged.

Pump delivers insuffi cient capacity

1.

 Incorrect voltage.

4.

 Excessive infl ow or pump not properly sized 

for application.

5.

 Discharge restricted.

6.

 Check valve stuck closed or installed 

backwards.

7.

 Shut-off valve closed.

8.

 Impeller jammed or loose on shaft, worn or 

damaged, impeller cavity or inlet plugged.

9. 

Pump may be airlocked.

10.

 Pump stator damaged/torn.

Pump cycles too frequently or runs 
periodically when fi xtures are not in use

6. Check valve stuck closed or installed 
backwards.
11. Fixtures are leaking.
15. Ground water entering basin.

Pump shuts off and turns on indepen-
dent of switch, (trips thermal overload 
protector). 

CAUTION!

  Pump may start 

unexpectedly. Disconnect power supply.

1. Incorrect voltage.
4. Excessive infl ow or pump not properly sized 
for application.
8. Impeller jammed or loose on shaft, worn or 
damaged, impeller cavity or inlet plugged
12. Excessive water temperature (Internal 
protection only).

Pump operates noisily or vibrates 
excessively

2c. Worn bearings, motor shaft bent
8. Debris in impeller cavity or broken impeller.
10. Pump running backwards.
13. Piping attachments to buiding structure too 
rigid or too loose.

E

N
G

L

I

S

H

Содержание 118531

Страница 1: ...duct changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J...

Страница 2: ...re lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secu...

Страница 3: ...N Hardware 300 series stainless steel CORD ENTRY 20 Ft 6m Cord with Plug Molded for strain relief and compression seal MOTOR Design Air Filled Insulation Class B SINGLE PHASE Permanent Split Capacitor...

Страница 4: ...ommended for general and light construction for sump and dewatering drainage for dewa tering manholes and transformer vaults for pit tunnel and trench dewatering and for flood fire and other emergency...

Страница 5: ...NUT TIGHT CHECK FREQUENTLY There shall be no openings in the casing of the electrical parts The operating voltage shall match the voltage rating of the motor E 2 Cable Requirements Special care shall...

Страница 6: ...operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is alw...

Страница 7: ...of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field...

Страница 8: ...Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covere...

Страница 9: ...posible que se hagan cambios a los productos Por esta raz n Crane Bombas y Sistemas se reserva el derecho de cambiar el producto sin previo aviso por escrito 420 Third Street 83 West Drive Bramton Pi...

Страница 10: ...opere la bomba sin que las cubiertas y los dispositivos de seguridad est n instalados Ponga siempre en su lugar los dispositivos de seguridad que se hayan retirado durante el mantenimiento o reparaci...

Страница 11: ...oxidable serie 300 ENTRADA DEL CORD Cord n con enchufe de 6m 20 pies Moldeado para reducci n de tensi n y sello de compresi n MOTOR Dise o Lleno de aire aislamiento clase B MONOFASICO Capacitor perman...

Страница 12: ...s para drenaje de sumideros y extracci n de agua para extracci n de agua de salas de transformadores y de pasos de hombre para extracci n de agua de pozos t neles y zanjas y para servicios de limpieza...

Страница 13: ...ones ptimas MANTENGA APRETADA LA TUERCA ESTANCADORA DEL CABLE VERIFIQUE CON FRECUENCIA La carcasa de las partes el ctricas deber estar libre de aberturas La tensi n de funcionamiento deber ser igual a...

Страница 14: ...6 E S P A O L...

Страница 15: ...n la seguridad y las condiciones Limpie toda obstrucci n de la cavidad del rotor y la entrada 9 Afloje la uni n ligeramente para dejar que salga el aire atrapado Verifique que el nivel de apagado del...

Страница 16: ...se base en las especificaciones del funcionamiento debe existir por escrito y llevar la firma de nuestro representante autorizado Debido a errores en las pruebas fuera de f brica si surge un conflicto...

Страница 17: ...ara asegurarse que los empleados no se expongan a peligros para su salud al manipular dicho material Todas las leyes y reglamentos pertinentes tendr n validez IMPORTANTE REGISTRO DE LA GARANTIA Su pro...

Страница 18: ......

Отзывы: