2. General information
If the desired chiller did not appear in the drop-down list, click on the arrowhead and select Refresh.
If you want to test what the service tool does without connecting it to chiller, you can also select Demo mode.
This will open the service tool and click on all service actions, without it affecting any device.
Image 2-7
Service actions
The following service actions can be performed using the service tool:
•
Primary Pump unit replacement. For more info on this procedure, see also"Primary pump replacement process", page 37.
•
Secondary unit replacement. For more info on this procedure, see also "Secondary cooling unit", page 47.
•
Refrigeration unit replacement. For more info on this procedure, see also "Refrigeration unit replacement process", page 55.
•
Tank cooling liquid replacement. For more info on this procedure, see also "Coolant procedures", page 25.
•
Liquid quality visual check. For more info on this procedure, see also "Cooling liquid visual check", page 35.
•
Pressurization unit replacement. For more info on this procedure, see also "Pressurization Unit", page 89.
•
Fan unit replacement. For more info on this procedure, see also "Fan unit", page 21.
•
Electronic unit replacement. For more info on this procedure, see also "Electronics Unit", page 67.
•
Pump inverter replacement. For more info on this procedure, see also "Pump inverter replacement", page 77.
•
Logic board replacement. For more info on this procedure, see also "Replacing the logic board", page 75.
•
SD logging status. For more info, see also "SD logging status", page 67.
•
Air removal procedure. For more info on this procedure, see also "First use of the Chiller service kit — Air removal procedure",
page 25.
While the service actions can be performed using the service tool only, it is strongly advised to read the ser-
vice manual
fi
rst to get a clear understanding of what needs to be done.
Diagnostic tests
The following diagnostics tests can be performed:
What it tests
Full test wizard
Full functionality test of the chiller.
1
Primary pump / bypass
valve
The primary cooling circuit is tested twice, once while the bypass valve is closed and again once
opened.
Secondary pump / valve
The functionality of the secondary circuit is tested, if available.
Pressure pump
The pressure pump is given a few short bursts. Open the tank cap slightly to see if cooling liquid
fl
ows through properly.
In order to open the tank cap, the same procedure can be used as when adding coolant to the tank.
For more info, see "Adding coolant to the tank", page 31.
Primary circuit
fl
ow test
Flow test of the primary cooling circuit
Secondary circuit
fl
ow test Flow test of the secondary cooling circuit.
2
The bypass tube from the service kit will be needed to perform the full test and the pump tests. Refer to the
test wizard to see how the tube needs to be connected.
1. Take into account that a full functionality test will take up to 25 minutes
2. Only available on Chiller units with the secondary cooling circuit installed
R5906015 ULC-30A 01/02/2018
11
Содержание ULC-30A
Страница 1: ...ULC 30A Service manual R5906015 01 01 02 2018...
Страница 4: ......
Страница 6: ...Table of contents Index 97 2 R5906015 ULC 30A 01 02 2018...
Страница 10: ...1 Safety 6 R5906015 ULC 30A 01 02 2018...
Страница 23: ...5 Covers 1 1 1 2 2 2 2 2 2 2 2 2 2 2 Image 5 4 Installing the 14 screws R5906015 ULC 30A 01 02 2018 19...
Страница 24: ...5 Covers 20 R5906015 ULC 30A 01 02 2018...
Страница 28: ...6 Fan unit 24 R5906015 ULC 30A 01 02 2018...
Страница 40: ...7 Coolant procedures 36 R5906015 ULC 30A 01 02 2018...
Страница 70: ...10 Refrigeration unit 66 R5906015 ULC 30A 01 02 2018...
Страница 92: ...11 Electronics Unit 88 R5906015 ULC 30A 01 02 2018...
Страница 100: ...A Appendix 96 R5906015 ULC 30A 01 02 2018...