To replace the lamp:
1. Disconnect power to the fixture. If the fixture has
been operating, wait for the lamp to cool before
handling.
2. Put on protective eyewear and gloves.
3. Using a wide tip, flat head screwdriver, loosen (
but
do not remove
) the lamp cover screw.
4. Holding the lamp assembly by its ceramic base,
rotate it from the
Lock
to the
Out
position and
carefully remove it from the fixture.
5. Remove all packaging materials from the new lamp.
6. Holding the new lamp assembly by its ceramic base, carefully insert it into the fixture and
rotate it to the lock position.
7. Tighten the lamp cover screw.
8. Reset the lamp hours to zero to track the lamp life, (see
Clr Lamp Time
in
Time Info
on page
23).
9. Optimize the new lamp.
Optimizing the Lamp
Optimize the lamp after replacement, or if there is a “hot spot” of brightness anywhere other than
the center of the light beam.
1. Orient the fixture so that the beam will project onto a flat, white surface at least 6.56 feet
(3m) away.
2. Turn the lamp on. Ensure the light beam is round and not oval. If necessary, adjust the pan
and tilt construct values until the beam is round.
Equipment surfaces may reach temperatures up to 110° C
(230° F). Allow the fixture to cool before handling.
CAUTION: This equipment is designed for use with a 850W HID lamp
only. Use of any other type lamp may be hazardous and
may void the warranty.
CAUTION: Do not squeeze the lamp glass while removing the existing
lamp from the socket. Lamp glass may shatter.
CAUTION: When handling the new lamp, avoid contact with the lamp
glass. If the lamp glass is soiled by oil or dirt from skin, gloves,
etc., clean the cold lamp glass with an alcohol wipe. A soiled
lamp could overheat and burst, causing damage to the fixture.
CHAPTER 6
General Maintenance
54
Technospot
TM
User Manual
To replace the lamp:
1. Disconnect power to the fixture. If the fixture has
been operating, wait for the lamp to cool before
handling.
2. Put on protective eyewear and gloves.
3. Using a wide tip, flat head screwdriver, loosen (
but
do not remove
) the lamp cover screw.
4. Holding the lamp assembly by its ceramic base,
rotate it from the
Lock
to the
Out
position and
carefully remove it from the fixture.
5. Remove all packaging materials from the new lamp.
6. Holding the new lamp assembly by its ceramic base, carefully insert it into the fixture and
rotate it to the lock position.
7. Tighten the lamp cover screw.
8. Reset the lamp hours to zero to track the lamp life, (see
Clr Lamp Time
in
Time Info
on page
23).
9. Optimize the new lamp.
Optimizing the Lamp
Optimize the lamp after replacement, or if there is a “hot spot” of brightness anywhere other than
the center of the light beam.
1. Orient the fixture so that the beam will project onto a flat, white surface at least 6.56 feet
(3m) away.
2. Turn the lamp on. Ensure the light beam is round and not oval. If necessary, adjust the pan
and tilt construct values until the beam is round.
Equipment surfaces may reach temperatures up to 110° C
(230° F). Allow the fixture to cool before handling.
CAUTION: This equipment is designed for use with a 850W HID lamp
only. Use of any other type lamp may be hazardous and
may void the warranty.
CAUTION: Do not squeeze the lamp glass while removing the existing
lamp from the socket. Lamp glass may shatter.
CAUTION: When handling the new lamp, avoid contact with the lamp
glass. If the lamp glass is soiled by oil or dirt from skin, gloves,
etc., clean the cold lamp glass with an alcohol wipe. A soiled
lamp could overheat and burst, causing damage to the fixture.