R5915190 /01
IEX series
10
to the mains through the power box from Barco this protection device is already incorporated and no extra
measures need to be taken. If this product is connected to the mains through a power distribution box from
another party, please verify that a Low Voltage Surge Protection Device according EN61643-11 or UL 1449 is
in place.
High leakage current:
The combination of multiple tiles in an installation results in increased levels of leakage current. In order to
avoid risk of electric shock due to high leakage current, proper grounding of the installation is required.
Flammable materials:
Keep flammable materials away from the installation (such as curtains). A lot of energy is transferred into heat.
The installation should be such that the amount of air flow required for safe operation of the equipment is not
compromised. Proper ventilation must be provided.
Risk of electric shock / Risk of fire:
Use single-phase power supply for an LED display with the total power consumption not exceeding 3 kW, and
three-phase power supply for an LED display with the total power consumption exceeding 3 kW.
Each power source cable should be protected by a circuit breaker or fuses rated 16 A / 250 VAC (15 A / 250
VAC in the USA and Canada). Note that one tile requires 100-240 VAC, 50-60 Hz.
To protect against risk of fire caused by overloading of power cables, the number of tiles connected in parallel
is limited, see table below.
Maximum tiles per power cable
Tile
Power source
USA/Canada
Rest of world
IEX1.2
110 - 180 VAC
7 tiles
9 tiles
180 - 240 VAC
14 tiles
18 tiles
IEX1.5
110 - 180 VAC
7 tiles
9 tiles
180 - 240 VAC
14 tiles
18 tiles
IEX1.8
110 - 180 VAC
7 tiles
9 tiles
180 - 240 VAC
14 tiles
18 tiles
IEX2.5
110 - 180 VAC
7 tiles
9 tiles
180 - 240 VAC
14 tiles
18 tiles
The power limits of the used power connectors needs to be followed.
ESD and LED's:
LED components used in IEX tiles are ESD (Electro-Static Discharge) sensitive. To prevent the possibility of
destroying LED components do not touch either in operation or while switched off. Always use ESD-gloves.
Disconnect device:
When the appliance inlets of the individual tiles are not accessible, the socket outlets supplying the rack shall
be installed near the equipment and be easily accessible, or a readily accessible general disconnect device
shall be incorporated in the fixed wiring.
This equipment MUST be earthed:
In order to protect against risk of electric shock, the installation should be properly grounded. Defeating the
purpose of the grounding type plug will expose you to the risk of electric shock.
Power system:
It is recommended to use a TN-S power distribution system (a power distribution system with a separate
neutral and grounding conductor) in order to avoid large ground current loops due to voltage differences in the
neutral conductor. The total electrical installation should be protected by an appropriately rated disconnect
switch, circuit breakers, over voltage protector and Ground Fault Current Interrupters. The installation shall be
done according to the local electrical installation codes. In Europe special attention should be given to HD
60364, Harmonization Document for electrical installation of buildings. In Germany VDE 0100 should be
adhered to. In America, special attention should be given to the National Electrical Code, ANSI/NFPA 70.
Содержание IEX Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Installation user guide IEX series...
Страница 4: ......
Страница 26: ...R5915190 01 IEX series 26 Installation and Wiring...
Страница 42: ...R5915190 01 IEX series 42 LED Display Control Setting...
Страница 65: ...65 R5915190 01 IEX series Image 6 6 Aging test Image 6 7 Screen test Startup Shutdown and Maintenance...
Страница 66: ...R5915190 01 IEX series 66 Startup Shutdown and Maintenance...
Страница 74: ...R5915190 01 IEX series 74 Image 7 17 Troubleshooting and Component Replacing...
Страница 77: ...77 R5915190 01 IEX series Environmental information A...
Страница 79: ......
Страница 80: ...www barco com R5915190 01 2022 11 30...