2. General
2.1
Installation requirements
Environment conditions
Table below summarizes the physical environment in which the DP-1200 digital projector may be safely operated or stored.
Environment
Operating
Non-Operating
Ambient Temperature
10 °C (50 °F) to 35 °C (95 °F)
-15°C (5°F) to 60°C (140°F)
Humidity
5% to 85% RH Non-condensed
5% to 95% RH Non-Condensed
Altitude
-60 (-197Ft) to 3000m (9843Ft)
-60 (-197Ft) to 10000m (32810Ft)
Let the projector acclimate to the ambient temperature after unpacking. Neglecting this may result in a startup
failure of the Light Processor Unit.
To accelerate the acclimation process of the projector strike the lamp. The heat of the lamp will warm up the
Light Processor Unit.
Cooling requirements
The projector is fan cooled and must be installed with suf
fi
cient space mainly in the front of the projector head, minimum 20 cm (8
inch) to ensure suf
fi
cient air
fl
ow. It should be used in an area where the ambient temperature, as measured at the projector head
air inlet and at the power unit air inlet, does not 35°C (+95°F).
The installation of an
exhaust system
is
MANDATORY
. The installed exhaust blower must remove an air volume of minimum
6,65
m
3
/min (235 CFM)
.
Power requirements
The DP-1200 digital projector operates from a nominal mono phase power net with a separate earth ground PE. The DP-1200 digital
projector requires 200–240 VAC, 50–60 Hz, 15 amps at 200 VAC with a separate earth ground PE. A label on the projector indicates
the nominal line voltage for which the projector was set at the factory.
The power cord required to connect the projector with the power net is not delivered with the projector. It is the responsibility of the
customer to provide the correct type of power cord. The cross-sectional area of the conductors in the power supply cord shall not
be less than 4 mm² or 10 AWG, minimum 300V.
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that the instrument panel
and cabinet be grounded. In no event shall this projector be operated without an adequate cabinet ground connection.
The AC supply must be installed by a quali
fi
ed electrician in conformance to local codes. Hardware, wire sizes and conduit types
must comply with local codes.
UPS requirements
The Uninterruptible Power Supply (UPS), also known as a Continuous Power Supply (CPS), must have an output voltage of 200-
240V at 50-60Hz and must be capable of delivering an output current of 5,5 amperes.
The connection between the UPS unit and the UPS inlet of the projector must be done with a certi
fi
ed AC power supply cord of
minimum 0,75 mm² or 18 AWG and minimum 300V.
C
AUTION
:
The 200–240V power outlet (UPS OUTLET) of the projector may not be used to provide the UPS
unit with power! The UPS OUTLET of the projector may only be used for connection to the UPS INLET of the
projector.
The DP-1200 digital projector does not have a built in UPS unit.
Projector weight
Do not underestimate the weight of the Barco DP-1200 digital projector. The projector weights about ±93 kg (±205 lb.) without lens.
Be sure that the pedestal on which the projector has to be installed is capable of handling
fi
ve (5) times the complete load of the
system.
10
R59770242 DP-1200 06/01/2009
Содержание DP-1200
Страница 1: ...DP 1200 Installation manual R59770242 02 06 01 2009 ...
Страница 12: ...1 Safety 8 R59770242 DP 1200 06 01 2009 ...
Страница 20: ...2 General 16 R59770242 DP 1200 06 01 2009 ...
Страница 29: ...3 Physical Installation 1 2 3 5 4 7 6 Image 3 11 R59770242 DP 1200 06 01 2009 25 ...
Страница 60: ...5 Lenses lens holder 56 R59770242 DP 1200 06 01 2009 ...
Страница 78: ...8 Starting up 74 R59770242 DP 1200 06 01 2009 ...
Страница 86: ...9 Projector registration Image 9 9 Add new owner 82 R59770242 DP 1200 06 01 2009 ...
Страница 104: ...10 Removal and installation of projector covers 100 R59770242 DP 1200 06 01 2009 ...
Страница 124: ...A Specifications A 3 Centre of gravity Centre of gravity 240 377 241 5 Image A 2 120 R59770242 DP 1200 06 01 2009 ...
Страница 128: ...A Specifications 124 R59770242 DP 1200 06 01 2009 ...
Страница 129: ...B Order Info B ORDER INFO Overview Spare part order info R59770242 DP 1200 06 01 2009 125 ...
Страница 132: ...Glossary 128 R59770242 DP 1200 06 01 2009 ...