HDMI 1.4 Supported Audio Formats
Format
Sample Rate
Sample coding
Bit depth
2 channels
32
44
48
88
96
L-PCM
16
5.1 channels
24
L-PCM
48
7.1 channels
20
L-PCM
48
8.18 ICMP(-X) reset
This procedure requires that ICMP(-X) version 1.2.4 or later is installed.
ICMP(-X) reset possibilities
•
The
Star
button on the local keypad (Not for C- and B-series)
•
The ICMP(-X) reset button ( labeled
Reboot ICMP
) in the GUI of the Communicator.
•
The ICMP(-X) reset button ( labeled
media server
) in the GUI of the Communicator.
•
The ICMP(-X) reset button ( labeled
Reboot media server
) in the GUI of the Commander.
•
The ICMP(-X) reset button ( labeled
Reboot media server
) in the GUI of the Web Commander.
•
The ICMP(-X) hardware reset button located on the front panel of the ICMP(-X) (Not recommended, use
only when all other reset possibilities are exhausted!)
How to reset the ICMP(-X)?
1.
Click on the
Control/ICMP/Reboot media server
in the GUI of the Web Commander
or
Click on
Control/ICMP/Reboot media server
in the GUI of the Commander
Note:
The behavior could be different depending the projector type. Please, refer to the projector
manual to obtain more details.
or
click on
Maintenance/Reboot action/media server
in the GUI of the Communicator (recommended)
or
click on
Contol/projector/power/Reboot ICMP
in the GUI of the Communicator (recommended)
or
press the
Star
button on the
local keypad
for a few seconds (Not for C- and B-series)
As a result the projector is safely prepared for the ICMP reboot. All ongoing events on the ICMP (e.g. ingest)
are requested to end. After a few seconds the ICMP is requested to restart. The READY LED on the front
panel of the ICMP starts to blink orange.
In case the ICMP (-X) is installed in DP4K-L series projector the lasers are switched off and the projector
remains in the same mode (e.g. Conditioned). The Star button on the local keypad starts blinking green. After
the reset of the ICMP(-X) the lasers are switched on again.
Once the READY LED lit continuous green the ICMP(-X) is up and running.
2.
Did the reset of the ICMP(-X) fail?
►
If yes,
perform a hardware reset as follows:
1.
switch off the lasers of the projector or switch of the projector lamp.
2.
press the ICMP(-X)
hardware reset button
a few seconds (reference 3 Image 8-22) .
Warning:
Resetting the ICMP(-X) with the hardware reset button may cause damage to the content on
the HDDs. A re-configuration of the whole system may be required!
Содержание Athena
Страница 1: ...ENABLING BRIGHT OUTCOMES Installation manual Athena ...
Страница 8: ...R5906790 04 Athena 8 ...
Страница 28: ...R5906790 04 Athena 28 Installation process ...
Страница 36: ...R5906790 04 Athena 36 Physical installation ...
Страница 58: ...R5906790 04 Athena 58 Input Communication ...
Страница 60: ...R5906790 04 Athena 60 ICMP X HDMI 2 0 specifications ICMP HDMI 1 4 specifications ICMP X reset ICMP X ...
Страница 100: ...R5906790 04 Athena 100 Starting up ...
Страница 126: ...R5906790 04 Athena 126 Lamp House ...
Страница 130: ...R5906790 04 Athena 130 Preventative maintenance actions ...
Страница 151: ...R5906790 04 Athena 151 1 Image 16 18 Removal and installation of the projector covers ...
Страница 152: ...R5906790 04 Athena 152 Removal and installation of the projector covers ...
Страница 160: ...R5906790 04 Athena 160 Specifications ...
Страница 168: ...R5906790 04 Athena 168 Pin configurations ...
Страница 169: ...169 R5906790 04 Athena Environmental information C ...
Страница 178: ...Glossary R5906790 04 Athena 178 ...
Страница 183: ...R5906790 04 Athena 183 ...