14
G.L.G. Australia Pty Ltd (ACN 001 185 002)
Building A2, Campus Business Park, 350-374 Parramatta Road
Homebush NSW 2140
Ph. 02 9735 4111
More Information?
www.barbequesgalore.com.au
Need more information or assistance in any way? You can call your Barbeques Galore store where
barbeque experts will be happy to help you. Just phone
Or visit our website at
Technical
Refer to the data sticker on your barbeque for jet sizes, gas
pressures etc. Please note that we are continually updating
change over time.
Gas connection:
located behind control knob:
30mm from base
260mm from inside edge
thr
1 3 0 0 3 0 1 3 9 2
55mm
330mm
560mm
BARBECUE SIDE BURNER MODEL
G.L.G. AUSTRALIA P/L HOMEBUSH N.S.W.
Gas Pressure:
LP - 2.75 kPa,
NG - 1.00 kPa
Injector orifice:
LP - 0.92 mm,
NG - 1.53 mm
Input per burner: LP – 11 MJ/hr, NG – 11MJ/hr
CLEARANCES FROM COMBUSTIBLE MATERIALS
Sides and back 300mm. Vertically above 1000mm.
IAPMO-R&T
OCEANA
TM
Gas Mark
IAPMO No
GMK 10275
AUSTRALIA AND NEW ZEALAND
GAS SAFETY CERTIFICA TION
®
DO NOT REMOVE
FOR USE WITH UNIVERSA
L LPG
-
-
-