Built-in Units Utilizing Liquid Propane Gas
NOTE:
When using Propane, EXTREME CAUTION should
be used to provide ample ventilation of vapor from the enclo-
sure. LP Gas vapor is heavier than air and SERIOUS
INJURY from a DANGEROUS EXPLOSION could occur if
LP Gas is allowed to accumulate in an enclosure and then
ignited. Both the Barbecue enclosure and LP cylinder enclo-
sure require venting that must be provided at the floor level
of the enclosure to allow any leaking LP Gas vapor to escape
(see
Figure 6
). Upper & lower ground-level vents (20 sq. in.
minimum each) MUST BE PROVIDED on both sides of built-
in construction. Please ask a Barbeques Galore associate for
full details.
NOTE:
When installing a barbecue equipped for liquid
propane in an island, the propane tank must be in a separate
enclosure that is completely isolated from the barbecue. It
must be cross-ventilated in accordance with the current
standard. The propane tank MUST NEVER be installed
directly under the barbecue.
NOTE:
Upper & lower ground-level vents (20 sq. in. mini-
mum each)
MUST BE PROVIDED
for combustion air on
both sides of built-in construction. Please ask a Barbeques
Galore associate for full details.
- 7 -
Depth
Width
Height
Side*
Rear*
6
minimum clear-
ance from cutout
(for hood)
Model
Height Width
Depth
Side* Rear*
B3808A
10"
38-3/4" 24-1/2"
14"
24"
non-combustible
construction
Built-in Model Cutout Dimensions &
Clearance to Combustibles
*
Rear & Side Clearances indicated are to combustible
construction
Figure 5
Vapors from products containing Chlorine and other caustic
chemicals can cause Stainless Steel flexible connectors to
corrode. THESE PRODUCTS SHOULD NOT BE STORED
IN AN ISLAND OR NEAR THE connector. Cleaning solu-
tions, Household Chemicals and Solder fluxes can also
cause pinholes if they come in contact with these connec-
tors and
MUST
be washed off immediately with water.
Stainless
Flexline
Non-combustible
Construction
Vented on
BOTH SIDES
of Island
Vented Access Door
CSA Approved Propane Regulator
CSA Approved
Rubber Gas Hose
QCC-1/OPD
Tank
Figure 6
Clamp down
flexline
Barbecues must be installed in accordance with CSA
specifications and all local building codes.
BAI08A
10"
52-3/4" 24-1/2"
24"
24"
n
WARNING
Содержание Grand Turbo B3808ALP
Страница 10: ...BAI08A LP BAI08ANG Parts Diagram 9 37A 76 77 92 58 70A 74 75 93 Optional ...
Страница 11: ...B3808ALP B3808ANG Parts Diagram 10 77A 71 72 93 94 96 95 77B 97 69 70 98 Optional ...
Страница 21: ...Figure 17 Figure 18 B5208ACT Models B3808ACT Models 20 ...
Страница 52: ...Barbeques Galore 949 597 2400 10 Orchard Road Suite 200 Lake Forest CA 92630 z z z ...