Built-in Units Utilizing Natural Gas
When connecting a built-in unit to the natural gas sup-
ply in your home, please ensure the pipe joint compound is
resistant to the action of natural gas. In addition, please
observe the following:
The barbecue and its individual shut-off valve must be
disconnected from the gas supply piping system during any
pressure
testing
of
that
system at test pressures in
excess
of
1/2
psi (3.5 kPa).
The barbecue must be isolated from the gas supply
piping system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping system
at test pressures
equal to or less than
psi (3.5 kPa)
The units are supplied from the factory equipped for
use with natural gas and includes a natural gas regulator.
If operation with propane gas is desired, you
must pur-
chase a Propane Model.
In addition, a
Propane Gas
Regulator MUST
be installed in the gas supply line from
the propane gas tank.
Please remember to check all gas connections for
leaks after the piping is completed. Follow the procedure
under the heading
"CAUTION: LEAK CHECKING."
CAUTION: BEWARE OF FLASHBACK
CAUTION: Spiders and small insects occasionally spin
webs or make nests in the
grill burner tubes during
transit and warehousing.
These webs can lead to a
gas flow obstruction which
could result in a fire in and
around the burner tubes.
This type of fire is known as a
FLASHBACK
and can
cause serious damage to your grill and create an unsafe
operating condition for the user.
Although an obstructed burner tube is not the only cause of
FLASHBACK
, it is the most common cause.
To reduce the chance of
FLASHBACK
, you must clean the
burner tubes before assembling your grill, and at least once
a month in late summer or early fall when spiders are most
active. Also perform this burner tube cleaning procedure if
your grill has not been used for an extended period of time.
BEFORE USING YOUR GRILL
To reduce the chance of
FLASHBACK
clean the burn-
er tubes and burners
before
fully assembling your grill.
Unscrew the bolt at the rear of the burner using a screw-
driver. Carefully lift each burner up and away from the gas
valve orifice, then refer to
Fig2
and perform one of these
three cleaning methods:
1. Bend a stiff wire, (a lightweight coat hanger works well)
into a small hook as shown below. Run the hook through
the burner tube and inside the burner several times to
remove any debris.
Type 1 connection per
ANSI Z21.58-2007/CS A
1.6-2007
Quick
Coupling Nut
CAUTION: When the appliance is not in use the gas
must be turned off at the tank.
Check all connections for LP Gas Leaks
Never
test for leaks with a flame. Prior to first use,
at the beginning of each season, or every time
your LP Gas tank is changed, you must check for
gas leaks. Follow these three steps:
Make a soap solution by mixing one part liquid
detergent and one part water.
Turn the grill Control Knobs to the full OFF
position, then turn the gas ON at source.
Apply the soap solution to all gas connections
indicated by the arrows. See diagram. If
bubbles appear in the soap solution the
connections are not properly sealed. Check
each fitting and tighten or repair as necessary.
!
!
If you have a gas leak that cannot be repaired
by tightening, turn off the gas at the source,
disconnect fuel line from your grill and call
1-800-752-3085
or your gas supplier for repair
assistance.
Disconnecting A Liquid Propane Gas (LPG)
Tank From Your Grill
Make sure the Burner Valves and LP Gas tank
valve are off. (Turn clockwise to close.)
Detach the hos e and regulator assembly from
the LP Gas tank valve by turning the Quick
Coupling Nut counterclockwise.
- 5 -
Regulator with Hose (LPG)
LP Gas Tank
Gas Valve / Manifold Assembly
1/2
n
Содержание Grand Turbo B3808ALP
Страница 10: ...BAI08A LP BAI08ANG Parts Diagram 9 37A 76 77 92 58 70A 74 75 93 Optional ...
Страница 11: ...B3808ALP B3808ANG Parts Diagram 10 77A 71 72 93 94 96 95 77B 97 69 70 98 Optional ...
Страница 21: ...Figure 17 Figure 18 B5208ACT Models B3808ACT Models 20 ...
Страница 52: ...Barbeques Galore 949 597 2400 10 Orchard Road Suite 200 Lake Forest CA 92630 z z z ...