If the length of line required does not exceed 50 feet, use
a 5/8" O.D. tube. One size larger should be used for
lengths greater than 50 feet.
Gas piping may be copper tubing, type K or L; polyeth-
ylene plastic tube, with a minimum wall thickness of .
062 inch; or standard weight (schedule 40) steel or
wrought iron pipe.
Copper tubing must be tin-lined if the gas contains more
than 0.3 grams of hydrogen sulfide per 100 cubic feet
of gas.
Plastic tubing is suitable only for outdoor, underground
use.
Gas piping in contact with earth, or any other material
which may corrode the piping, must be protected
against corrosion in an approved manner.
Underground piping must have a minimum of 18"
cover.
Gas Line Piping
ܱ ²±¬ «-» ¿² ±°»² º´¿³» ¬± ½¸»½µ º±® ¹¿-
´»¿µ-ò Þ» -«®» ¬¸»®» ¿®» ²± -°¿®µ- ±® ±°»²
º´¿³»- ·² ¬¸» ¿®»¿ ©¸·´» §±« ½¸»½µ º±® ¹¿-
´»¿µ-ò ̸·- ©·´´ ®»-«´¬ ·² ¿ º·®» ±® »¨°´±-·±²
©¸·½¸ ½¿² ½¿«-» -»®·±«- ¾±¼·´§ ·²¶«®§ ±®
¼»¿¬¸ô ¿²¼ ¼¿³¿¹» ¬± °®±°»®¬§ò
ÜßÒÙÛÎ
All connections and joints must be thoroughly tested
for leaks in accordance with local codes and all listed
procedures in the latest edition of A
NSI Z21.58-
2007
Test Connections
/
CSA 1.6 -
2007
- 4 -
The Quick Disconnect fitting can be installed
horizontally,or pointing downward.DO NOT
install the fitting with the opening pointing
upward because the fitting could collect water
and debris.
The Dust Covers (plastic plugs) provided with
the Quick Disconnect help keep the open
ends clean while disconnected.
The outdoor connector must be firmly attached to
a ridged permanent construction.
The Quick Disconnect MUST BE installed above
ground.
ÉßÎÒ×ÒÙæ
Do not route the 10 foot Quick
Disconnect Hose under a deck. The hose must
be visible and inspected prior to each grill use.
Ю±°¿²» Ù¿- Í¿º»¬§ ײ-¬®«½¬·±²-
Use a clean paintbrush and a 50/50 mild soapand
water solution.
Brush soapysolution onto LP Gas tank in the areas
indicated by the arrows. See diagram.
If growing bubblesap ear do not use or move the
LP Gas tank. Call an LP GasSu lier or your Fire
Department.
All leak tests must be repeatedeach time your LP Gas
tankis excha ed or refilled.
When checking for gas leaksdonot smoke.
Do not use an open flame to check for gas leaks.
Your grill must be leak tested outdoors in a well-
ventilated area, away from ignition sources such as
gas fired or electrical a liances. During the leak te t,
keep your grill away from open flamesor sparks.
Do not use household cleaning agents. Damage to
gas assembly components can result.
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
If growing bubbles appear do not use or move
the LP Gas tank. Contact an LP Gas Supplier
or your fire department!
!
!
Turn all Burner Valves to the OFF position.
Inspect the valve connection port and regulator
assembly for damage or debris. Remove any
debris. Never use damaged or plugged equip-
ment.
Connect the regulator assembly to the tank valve
and HAND TIGHTEN nut clockwise to a full stop.
DO NOT use a wrench to tighten because it could
damage the Quick Coupling Nut and result in a
hazardous condition.
Open the tank valve 1/4 to 1/2 of a turn (coun-
terclockwise) and use a soapy water solution to
check all connections for leaks before attempting
to light your grill. See "Checking for LP Gas
Leaks". If a leak is found, turn the tank valve off
and do not use your grill until the leak is repaired.
LP Gas Model only:
Connect Regulator with Hose to your LP Gas Tank
p
pp
s
pp
n
a g
WARNING
!
!
This appliance, when installed, must be electri-
cally grounded in accordance with local codes
or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70,
or the
Canadian Electrical Code, CSA C22.1.
Keep any electrical supply cord and the fuel
supply hose away from any heated surfaces.
•
•
Содержание Grand Turbo B3808ALP
Страница 10: ...BAI08A LP BAI08ANG Parts Diagram 9 37A 76 77 92 58 70A 74 75 93 Optional ...
Страница 11: ...B3808ALP B3808ANG Parts Diagram 10 77A 71 72 93 94 96 95 77B 97 69 70 98 Optional ...
Страница 21: ...Figure 17 Figure 18 B5208ACT Models B3808ACT Models 20 ...
Страница 52: ...Barbeques Galore 949 597 2400 10 Orchard Road Suite 200 Lake Forest CA 92630 z z z ...