Connections on Opti-Air system
Table 5: Connections on the Opti-Air system
Item
Description
M1
Motor 1
Motor 1 drives the control valve
of the primary air inlet
M2
Motor 2
Motor 2 drives the control valve
of the secondary air and air-
wash inlet
P
Pressure measurement
Connection for the pressure
line on the chimney to measure
the chimney draught.
6V
Power connection
Use this connection for the 6
VDC power adapter.
+ = red wire
- = black wire
Battery symbol
9V battery back-up
The 9V battery back-up makes
sure the air valves go to a safe
position when there is an elec-
tric power interruption.
+ = brown wire
- = blue wire
NTC
Room temperature measure-
ment
Measures the room tempera-
ture with an NTC element (re-
sistance measurement)
+ and -- is black wire
TK
Thermocouple connection
Measures the gas temperature
of the flue gasses in the appli-
ance
+ = green wire
- = white wire
Technical data
34
Evolux 100-45
Содержание Evolux 100-45
Страница 1: ...I Installation and maintenance manual Evolux 100 45 Serial number Production date...
Страница 35: ...8 8 Dimensions 8 1 Evolux 100 45 with 3 sided frame Dimensions Evolux 100 45 35...
Страница 36: ...8 8 2 Evolux 100 45 with 3 sided frame and convection casing Dimensions 36 Evolux 100 45...
Страница 39: ...8 8 5 Evolux 100 45 with 3 sided frame and fire screen Dimensions Evolux 100 45 39...
Страница 40: ...8 8 6 Evolux 100 45 with 4 sided frame Dimensions 40 Evolux 100 45...
Страница 42: ...8 8 8 Evolux 100 45 with 4 sided frame and convection casing Dimensions 42 Evolux 100 45...
Страница 44: ...8 8 10 Evolux 100 45 with 4 sided frame and fire screen Dimensions 44 Evolux 100 45...
Страница 48: ...Y Your Barbas dealer 002 07 10 2020...