background image

IInstallation and

maintenance manual

Evolux 100-45

 

Serial number:

Production date:

Содержание Evolux 100-45

Страница 1: ...I Installation and maintenance manual Evolux 100 45 Serial number Production date...

Страница 2: ...se without the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this document...

Страница 3: ...f the appliance 15 5 1 3 Requirements on the chimney 16 5 2 Preparation for installation 17 5 3 Installation procedure 17 5 3 1 Install the appliance 17 5 3 2 Horizontally align the appliance 18 5 3 3...

Страница 4: ...frame with Opti Air and convection ventilator 38 8 5 Evolux 100 45 with 3 sided frame and fire screen 39 8 6 Evolux 100 45 with 4 sided frame 40 8 7 Evolux 100 45 with 4 sided frame and air box 41 8...

Страница 5: ...d function Bladel August 31 2020 place and date of issue Signature The performance of the product identified in point 1 is in conformity with the declared performance in point 7 This declaration of pe...

Страница 6: ...er 15 2020 place and date of issue Signature Release of dangerous substances Pass Emission of combustion products Mechanical resistance to carry a chimney flue Surface temperature Risk of burning fuel...

Страница 7: ...w a typical setup The illustrations are for instructional use only 2 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety chapter...

Страница 8: ...n air inlet of the appliance In all other cases the appliance is not a room sealed appliance and the data for leak tightness as given in 7 are not valid Front top view of the appliance A Door handle B...

Страница 9: ...G Heat shield steel H Lower baffle ceramic I Upper baffle vermiculite L Secondary air inlet M Air wash inlet N Combustion air inlet O Convection air inlet S Adjustable feet Y Chain cover Description E...

Страница 10: ...lator combustion air inlet box N Combustion air inlet P Convection ventilator option Q Convection ventilator Combustion air inlet box option S Adjustable feet T Adjustable height frame option Y Chain...

Страница 11: ...set The appliance can be installed with a convection set The convection set collects the heated convection air from the appliance and releases this air into the room A convection ventilator combustion...

Страница 12: ...s intended for intermittent use and is not intended for continuous use The appliance is intended to heat the room by direct heating It is not allowed to connect the appliance to a central heating inst...

Страница 13: ...ilator A Combustion air inlet B Convection air inlet C Chimney breast ventilation air inlet D Chimney E Insulating material F Convection air outlet G Chimney breast ventilation air outlet H High adjus...

Страница 14: ...Do not use masking tape on the appliance Masking tape can damage the finish of the appliance Do not use fiberglass rockwool or any other sort of insulation material These materials produce a pungent o...

Страница 15: ...e is installed is properly ventilated 5 1 2 Requirements on the installation of the appliance Do not install the appliance against a combustible rear wall or combustible side wall The appliance must b...

Страница 16: ...our dealer or chimney sweeper for advice Make sure the flue system obeys the national and local applicable regulations Do not connect more than one appliance to the same chimney The flue system must h...

Страница 17: ...dures are indicated with optional 5 3 1 Install the appliance Caution Do not lift the appliance with any kind of forklift This will cause damage to the underside of the appliance Only use the carrying...

Страница 18: ...e contra weight a little and put the chain on the chain wheel 7 Make sure the door opens and closes correctly 8 Attach the chain cover on the appliance and tighten the nuts 9 Make again sure the door...

Страница 19: ...lue lining system to improve the performance of the appliance It is possible to connect the appliance on a flue with an inner diameter of minimum 200mm Use a correct adapter on the flue connector Impo...

Страница 20: ...building through a flexible pipe that is connected to one of these the combustion air inlet of the appliance the combustion air inlet on the combustion air box the combustion air inlet on the convecti...

Страница 21: ...ollar adaptor Secure the connection with a clamp 6 Connect the other end with the hole in the floor or the grate in the wall Use a suitable connector 5 5 3 5 Connect the convection set optional Connec...

Страница 22: ...aptors in the open outlet openings 5 Bend out the 3 lips on each collar adaptor to attach the collar adaptor on the outlet opening 6 Connect the flexible aluminum pipes B on the collar adaptors A Use...

Страница 23: ...thickness of at least 5 cm on the top of the appliance and the sides and back of the appliance Keep approximately 10 cm free between the front of the appliance and the front of the fireplace 5 3 7 Bui...

Страница 24: ...load bearing wall Caution Put a non combustible insulating plate with a thickness of at least 40 mm and a thermal conductivity of not more than 0 10 W m K on a distance of at least 50 mm from a combu...

Страница 25: ...air inlet grate 2 If applicable identify the positions where the fitting boxes of the convection air inlets and convection air outlets must be put Refer to 5 1 2 for requirements on minimum distances...

Страница 26: ...le sided adhesive tape on the 2 inside surfaces of the stone bar Important To make sure the adhesive tape adheres firmly clean the surfaces of the stone bar and the adapter Consult the supplier of the...

Страница 27: ...re the fire screen closes and opens easy 3 If applicable Make sure the control lever moves easy to left and right without undue noise 4 Make sure all cast iron plates and the baffles are in the correc...

Страница 28: ...ray 4 Examine the two baffles for damage Replace when damaged Refer to 6 6 for access to the baffles 5 Clean both sides of the glass with glass spray or ceramic hob cleaner 6 Clean the inside of the a...

Страница 29: ...2 inlet openings for the convection air 2 Clean the 2 outlet openings for the convection air 6 5 Chimney Note It is recommended to contact a registered chimney sweep company to inspect and clean the...

Страница 30: ...hield from the appliance 6 6 2 Remove the lower baffle 1 Push up the left side of the lower baffle 1 2 Rotate the lower baffle a little bit forward 3 Lower the right side of the lower baffle 3 and rem...

Страница 31: ...Place the lower baffle 3 Place the heat shield and screw the socket screw against the heat shield and tighten with the nut 6 8 Opti Air system It is recommended to change the 9 V back up battery ever...

Страница 32: ...output indicative 80 84 Indirect heating function No No Leak rate at 10 Pa 2 7 m3 h at 273 K 1013 hPa 2 7 m3 h at 273 K 1013 hPa Emissions at 13 O2 273 K 1013 h a carbon monoxide CO 0 05 vol 645 mg Nm...

Страница 33: ...ir inlet box Pipe connection with diameter of 125 mm on the appliance or 3 holes with diameter of 125 mm on the optional convection ventilator combustion air inlet box Available options Convection ven...

Страница 34: ...draught 6V Power connection Use this connection for the 6 VDC power adapter red wire black wire Battery symbol 9V battery back up The 9V battery back up makes sure the air valves go to a safe positio...

Страница 35: ...8 8 Dimensions 8 1 Evolux 100 45 with 3 sided frame Dimensions Evolux 100 45 35...

Страница 36: ...8 8 2 Evolux 100 45 with 3 sided frame and convection casing Dimensions 36 Evolux 100 45...

Страница 37: ...Evolux 100 45 with 3 sided frame and air box With optional adjustable height frame 3 Combustion air inlet openings 125 mm at the left side right side and bottom of the air box Dimensions Evolux 100 4...

Страница 38: ...With optional adjustable height frame 3 Combustion air inlet openings 125 mm at the left side right side and bottom of the air box 2 Convection air inlet openings 125 mm at the left side and right si...

Страница 39: ...8 8 5 Evolux 100 45 with 3 sided frame and fire screen Dimensions Evolux 100 45 39...

Страница 40: ...8 8 6 Evolux 100 45 with 4 sided frame Dimensions 40 Evolux 100 45...

Страница 41: ...Evolux 100 45 with 4 sided frame and air box With optional adjustable height frame 3 Combustion air inlet openings 125 mm at the left side right side and bottom of the air box Dimensions Evolux 100 4...

Страница 42: ...8 8 8 Evolux 100 45 with 4 sided frame and convection casing Dimensions 42 Evolux 100 45...

Страница 43: ...With optional adjustable height frame 3 Combustion air inlet openings 125 mm at the left side right side and bottom of the air box 2 Convection air inlet openings 125 mm at the left side and right si...

Страница 44: ...8 8 10 Evolux 100 45 with 4 sided frame and fire screen Dimensions 44 Evolux 100 45...

Страница 45: ...11 Dimensions decorative stone bar Make sure the dimensions of the decorative stone bar supplied by a third party supplier comply with the dimensions in the picture hereunder Dimensions Evolux 100 45...

Страница 46: ...hey have manifested themselves 3 Complaints will only be accepted if they are reported to the Barbas dealer together with the serial number of the Barbas appliance which is stated on the front of the...

Страница 47: ...oes not automatically imply that Barbas Bellfires B V also accepts liability for any possible damage The liability of Barbas Bellfires B V never extends further than that stated in these warranty cond...

Страница 48: ...Y Your Barbas dealer 002 07 10 2020...

Отзывы: