32
Thanks to this function you can adjust the squelch in 5 different levels:
•
OFF
: opened squelch. With this setting, the radios will detect all signals, also the weakest ones, but will also receive the background noise or
undesired signals.
•
Levels 1- 5
: level 1 (lowest squelch level), level 5 (highest squelch level).
If the squelch is set to the highest level, the radio will receive the strongest signals only.
(3) Power save (Power Save)
–
MENU + 3
When the radio is in standby, the power saving function reduces battery consumption. Turning on will be more power efficient, but you may
miss the first few syllables before RX turns on.
(4) VOX Function (Vox Switch)
–
MENU + 4
The VOX feature allows hands-free calls without using the PTT button. As soon as you speak into the microphone, communication will start
automatically.
ON: Activate the VOX function;
Off: Turns off the VOX function.
(5) VOX Level (Vox Level)
–
MENU + 5
From this menu, you can select the VOX sensitivity level.
The selection range is from 1 to 9
。
Note: Level 1 is the least sensitive, while level 9 is the most sensitive.
The VOX feature is not enabled when the radio is in scan or FM radio mode.
(6) VOX Delay
–
MENU + 6
When the VOX is enabled, set up the VOX delay to help to extend the transmission time to avoid stopping a transmission too early.
Range 0.5
–
2.0 seconds. Step 0.1 second. Default 1 seconds
(7) Time-Out-Timer (TOT)
–
MENU + 7
The Time-Out Timer (TOT) sets the duration that the radio can continuously transmit before transmission is automatically terminated. This
feature is used to prevent any single user from occupying a channel for too long.
Range: Off, 15
–
180 seconds, Step 15 seconds. Default 60 seconds.