Model
Description
SC22-3-S
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display
SC22-3-SU1
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display (includes
programming tool and USB cable)
SC22-3E-S
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display and Ethernet
SC22-3E-SU1
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display and Ethernet
(includes programming tool and USB cable)
11.5 Muting Module
Provides the muting capability for the EZ-SCREEN LS Basic. See Banner manual
for more information and
additional cabling options.
Model
Description
MMD-TA-11B
DIN-mount Muting module
2 N.O. safety outputs (6 amps), 2 or 4 muting inputs, SSI, override input; IP20; terminal
connections
MMD-TA-12B
2 OSSD outputs, 2 or 4 muting inputs, SSI, override input; IP20; terminal connections
11.6 Interface Modules
IM-T-..A interface modules provide forced-guided, mechanically-linked relay (safety) outputs for the EZ-SCREEN LS Basic
System with an 8-pin interconnect (with EDM function). The IM-T-..A interface module is required to be monitored by the
EDM function and should not be used with EZ-SCREEN LS Basic with a 5-pin interconnection (P5). See Banner datasheet
p/n
for more information.
Model
Description
IM-T-9A
Interface module, 3 normally open (N.O.) redundant-output 6 amp contacts
IM-T-11A
Interface module, 2 normally open (N.O.) redundant-output 6 amp contacts, plus 1 normally closed (N.C.) auxiliary
contact
11.7 Contactors
If used, two contactors per EZ-SCREEN LS Basic System that are monitored by the EDM circuit are required and should
for
more information.
Model
Description
11-BG00-31-D-024
10 amp positive-guided contactor, 3 N.O., 1 N.C.
BF1801L024
18 amp positive-guided contactor, 3 N.O., 1 N.C. (N.C. contact rated at 10 amps)
EZ-SCREEN
®
LS Basic Safety Light Screen
64
www.bannerengineering.com - Tel: 763.544.3164