MQDEC-4xxSS 4-pin M12/Euro-style QD to M12/Euro-style QD (female-male) cordsets—Use MQDEC-4...SS cordsets to connect to
devices that do not or cannot have earth ground on pin 5 of a 5-pin QD. In such situations, earth ground must be provided via the
mounting brackets. These cordsets have black PVC cables and black overmolds. The female M12 QD connector has a empty hole (no
connection) in the pin 5 position to allow mating with a 5-pin male QD.
Model
Length
Banner Cordset Pinout/Color Code
M12 Connector (female face view)
MQDEC-401SS
0.3 m (1 ft)
Pin
Color
Emitter
Function
Receiver
Function
1
Brown
+24 V dc
+24 V dc
2
White
no connection
OSSD2
3
Blue
0 V dc
0 V dc
4
Black
no connection
OSSD1
5
n/a
no connection
no connection
40 Typ.
[1.58"]
ø 14.5 [0.57"]
M12 x 1
44 Typ.
[1.73"]
ø 14.5 [0.57"]
M12 x 1
2
3
4
1
5
MQDEC-403SS
0.9 m (3 ft)
MQDEC-406SS
1.8 m (6 ft)
MQDEC-412SS
3.6 m (12 ft)
MQDEC-420SS
6.1 m (20 ft)
MQDEC-430SS
9.2 m (30 ft)
MQDEC-450SS
15.2 m (50 ft)
DELSE-..1D RD to M12/Euro-style QD (male) cordsets—Use DELSE-..1D cordsets to create or replace a 300 mm pigtail M12/Euro-style
quick disconnect (models ending in P8 or P5).
Model
Length
Banner Cordset Pinout/Color Code
DELSE-81D
0.3 m (1 ft)
Pin
Color
Emitter
Function
Receiver
Function
1
Brown
+24 V dc
+24 V dc
2
Or/Bk
Fault
Fault
3
Orange
ID in
EDM
4
White
no connection
OSSD2
5
Black
no connection
OSSD1
6
Blue
0 V dc
0 V dc
7
Gn/Ye
Gnd/Chassis
Gnd/Chassis
8
Violet
Scan Code
Scan Code
DELSE-51D
0.3 m (1 ft)
Pin
Color
Emitter
Function
Receiver
Function
1
Brown
+24 V dc
+24 V dc
2
White
no connection
OSSD2
3
Blue
0 V dc
0 V dc
4
Black
no connection
OSSD1
5
Gn/Ye
Gnd/Chassis
Gnd/Chassis
11.1.3 Splitter Cordsets
Model CSB splitter cordsets allow easy interconnection between an EZ-SCREEN 8-pin receiver and its 8-pin emitter,
providing a single trunk cable for the optional "swapable" hookup. The model DEE2R-.. double-ended cables may be used
to extend the lengths of the QD trunk, branch #1, or branch #2. Branch #1 and branch #2 cable sections are 300 mm (11.8
in) long. The model QDE-8..D single-ended cables may be used to extend the QD trunk for cut-to-length applications.
EZ-SCREEN
®
LS Basic Safety Light Screen
www.bannerengineering.com - Tel: 763.544.3164
61