Generic Wiring Diagram—8-pin Receiver and IM-T-9A Interface Module
S1
S2
Y1
Y2
Y3
Y4
14
24
34
13
23
33
S4
S3
IM-T-9A ***
K2
K1
MPCE
2
MPCE
1
Machine
Control
Feedback (optional)
8-pin male
M12/Euro-style
(face view)
Bn (Pin #1)
Gn/Ye (#7)
Bu (#6)
Bk (#5)
Wh (#4)
Vi (#8)
Or (#3)
Or/Bk (#2)
Fault Out
*
*
+24V dc
0V dc
Scan Code **
Figure 34. Generic Wiring Diagram—IM-T-9A Interface Module (1-Channel EDM)
* Installation of transient (arc) suppressors across the coils of MPCE1 and MPCE2 is recommended (see WARNING).
** Scan Code 1: not connected or connected to 0 V dc (as shown). Scan Code 2: connect to 24 V dc.
*** Other interfacing modules and solutions available. See the Banner Engineering catalog or website for more information.
Note: See the IM-T-..A module datasheet (p/n
) for complete installation instructions.
WARNING: Use of Transient Suppressors
If transient suppressors are used, they MUST be installed across the coils of the machine control
elements. NEVER install suppressors directly across the contacts of the IM-T-..A Module. It is possible
for suppressors to fail as a short circuit. If installed directly across the contacts of the IM-T-..A Module, a
short-circuit suppressor creates an unsafe condition. Failure to follow these instructions could result in
serious injury or death.