9 Troubleshooting
9.1 Lockout Conditions
A Lockout condition causes all of the EZ-SCREEN LS Basic OSSD outputs to turn or remain Off, sending a stop signal to
the guarded machine. Each sensor provides diagnostic error codes to assist in the identification of the cause(s) of lockouts
(see
Receiver Error Codes
and
Emitter Error Codes
) ).
The following tables indicate a sensor lockout condition:
Table 9: Receiver Lockout Conditions
Run mode indicator
Off
Status indicator
Flashing Red
Alignment indicators
Off
Diagnostic display
Error code (flashing)
Table 10: Emitter Lockout Conditions
Status indicator
Flashing Red
Diagnostic Display
Error code (flashing)
If both the emitter and its corresponding receiver do not have the same scan code setting, the receiver indicates that Beam
1 is blocked (the Diagnostic display indicating "C" "H" "1" as shown in
on page 49). This is not considered a
lockout and can occur if the Scan Code input is not wired the same for both sensors or if the EDM circuit has not been re-
wired for one-channel monitoring in retrofit installations of two-channel EDM applications (see the warning in
9.2 Recovery Procedures
To recover from a Lockout condition, correct all errors, power the sensor down, wait a few seconds, and then power the
sensor back up.
WARNING: Lockouts and Power Failures
Power failures and Lockout conditions are indication of a problem and must be investigated immediately
by a Qualified Person
9
. Attempts to continue to operate machinery by bypassing the Banner device or
other safeguards is dangerous and could result in serious injury or death.
WARNING: Shut Down Machinery Before Servicing
The machinery to which the Banner device is connected must not be operating at any time during major
service or maintenance. This may require lockout/tagout procedures (refer to OSHA1910.147, ANSI
Z244-1, ISO 14118 or the appropriate standard for controlling hazardous energy). Servicing the Banner
device while the hazardous machinery is operational could result in serious injury or death.
9.2.1 Receiver Error Codes
Diagnostic
Display
10
Error Description
Cause of Error and Appropriate Action
Output Error
Error is caused by:
• one or both outputs
being shorted to a
power supply (high or
low)
• by shorting OSSD 1 to
OSSD 2
• by an overload (greater
than 0.5 A)
• Disconnect the OSSD loads and cycle power to the receiver.
• If the error clears, the problem is in the OSSD load(s) or in the
load wiring.
• If the error continues with no load connected, replace the
receiver.
9
A person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and
experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work.
10
Multiple-digit codes are sequential, followed by a pause.
EZ-SCREEN
®
LS Basic Safety Light Screen
54