Output Indicator
• On—Output is on
• Off—Output is off
Stability Indicator (STB)
• On—Stable signal within the specified sensing range
• Flashing—Marginal signal, the target is outside the
limits of the specified sensing range, or a multiple
peak condition exists
• Off—No target detected within the specified sensing
range
Active TEACH Indicators (DYN, FGS, and BGS)
• DYN, FGS, and BGS all off—Two-point TEACH
mode selected (default)
• DYN on—Dynamic TEACH mode selected
• FGS on—Foreground suppression TEACH mode
selected
• BGS on—Background suppression TEACH mode
selected
• DYN, FGS, and BGS all on—Dual TEACH mode
selected
1.4.2 Buttons
Use the sensor buttons (SELECT)(TEACH), (+)(CH1/CH2), and (-)(MODE) to program the sensor.
(SELECT)(TEACH)
• Press to select menu items in Setup mode
• Press and hold for longer than 2 seconds to start the
currently selected TEACH mode (the default is two-
point TEACH)
(+)(CH1/CH2)
• Press to navigate the sensor menu in Setup mode
• Press to change setting values; press and hold to
increase numeric values
• Press and hold for longer than 2 seconds to switch
between Channel 1 and Channel 2
(-)(MODE)
• Press to navigate the sensor menu in Setup mode
• Press to change setting values; press and hold to
decrease numeric values
• Press and hold for longer than 2 seconds to enter
Setup mode
Note: When navigating the menu, the
menu items loop.
Q5X Laser Triangulation Sensor with Background Suppression
www.bannerengineering.com - Tel: +1.763.544.3164
5