3.6 TEACH Procedures
Use the following procedures to teach the sensor.
To cancel a TEACH procedure, press TEACH for longer than 2 seconds, or hold the remote input high for longer than 2
seconds.
momentarily displays when a TEACH procedure is canceled.
After any teach operation starts, the display temporarily flashes CH1 or CH2 to confirm which channel is currently selected.
3.6.1 Two-Point Static Background Suppression
Two-point TEACH sets a single switch point. The sensor sets the switch point between two taught target distances, relative
to the shifted origin location.
1
Switch
Point
Value
4
2
Press and
Hold > 2s
Press
again
3
Press
again
5
Figure 20. Two-Point Static Background Suppression (Light Operate shown)
Note: The sensor must be set to
=
to use the following instructions.
Note: To program the sensor using remote input, remote input must be enabled (
=
).
1. Present the target.
Method
Action
Result
Push Button
Present the first target. The sensor-to-target distance must be within the
sensor's range.
The target's measurement value displays.
Remote Input
2. Start the TEACH mode.
Method
Action
Result
Push Button
Press and hold TEACH for longer than 2 seconds.
and
flash alternately on
the display. The DYN, FGS, and BGS
indicators flash.
Remote Input
No action required.
N/A
3. Teach the sensor.
Method
Action
Result
Push Button
Press TEACH to teach the target.
The sensor is taught the first target.
,
, and the current
distance measurement flash alternately on
the display. The DYN, FGS, and BGS
indicators flash.
Remote Input
Single-pulse the remote input.
T
Q5X Laser Triangulation Sensor with Background Suppression
www.bannerengineering.com - Tel: +1.763.544.3164
21