Note: To program the sensor using remote input, remote input must be enabled (
=
).
1. Present the target.
Method
Action
Result
Push Button
Present the first target. The sensor-to-target distance must be within the
sensor's range.
The target's measurement value displays.
Remote Input
2. Start the TEACH mode.
Method
Action
Result
Push Button
Press and hold TEACH for longer than 2 seconds.
and
flash alternately on
the display. The DYN indicator flashes.
Remote Input
No action required.
N/A
3. Teach the sensor.
Method
Action
Result
Push Button
Press TEACH to teach the target.
The sensor begins sampling target
distance information and
and
flash alternately on the display.
The DYN indicator flashes.
Remote Input
Single-pulse the remote input.
T
4. Present the targets.
Method
Action
Result
Push Button
Present additional targets. The sensor-to-target distance must be within the
sensor's range.
The sensor continues to sample target
distance information and
and
flash alternately on the display.
The DYN indicator flashes.
Remote Input
5. Teach the sensor.
Method
Action
Result
Push Button
Press TEACH to stop teaching the sensor.
The new switch point flashes rapidly and
the sensor returns to Run mode.
Remote Input
Single-pulse the remote input.
T
Table 3: Expected TEACH Behavior for Dynamic Background Suppression
See
Figure 24
on page 33 for the minimum object separation.
Condition
TEACH Result
Display
Two valid distances that are greater than or
equal to the horizontal minimum object
separation
Sets a switch point between the two taught distances.
The switch point distance flashes on the
display.
Two valid distances that are less than the
horizontal minimum object separation
Sets a switch point in front of the furthest taught distance
by the horizontal minimum object separation.
and the switch point distance flash
alternately on the display.
One valid distance with one invalid TEACH
point
Sets a switch point between the one taught distance and
the maximum range.
and the switch point distance flash
alternately on the display.
Two invalid TEACH points
Sets a switch point for the currently selected channel at
200 cm.
and the switch point distance flash
alternately on the display.
Q5X Laser Triangulation Sensor with Background Suppression
www.bannerengineering.com - Tel: +1.763.544.3164
23