2. Set the Minimum Pass Count and Maximum Pass Count as appropriate. In the Demo, both are set to 1.
3. Test the complete range of good and bad samples to make sure that the sensor accepts good parts and rejects bad.
4. To complete the Match application setup, set triggering as appropriate for your application.
4.5.1 Remote Teach
The Remote Teach function is a method of remotely updating inspection parameters while the iVu sensor is running. Remote Teach is
only available when the iVu is configured as a Match sensor. The sequence of events for executing a Remote Teach as follows:
1. With the sensor Ready, pulse the Remote Teach line.
2. The sensor recognizes that the Remote Teach line has been pulsed and waits for the next valid trigger.
3. At the next valid trigger, Ready goes inactive (the Green Ready LED shuts OFF), and the sensor acquires a new image.
4. The sensor learns the new pattern and performs the analysis.
iVu Series Image Sensor
Rev. E
www.bannerengineering.com - tel: 763-544-3164
53