+24 V DC
+
0 V DC
S1
S2
Y4
Y2
14
24
34
S3
S4
Y3
Y1
13
23
33
K2
K1
Machine
Control
Feedback (optional)
MPCE
2
MPCE
1
Receiver
8-pin male
face view
Aux. out
Bn (Pin #1)
Bu (#6)
Bk (#5)
Wh (#4)
Or (#3)
Or/Bk (#2)
*
*
Reset**
Load
* Installation of transient (arc) suppressors across the coils of MPCE1 and MPCE2 is recommended.
** Trip (auto reset) — Not connected
*** Other interfacing modules and solutions available.
for more QDE-8D cordset information.
WARNING:
Properly install arc or transient suppressors
Failure to follow these instructions could result in serious injury or death.
Install any suppressors as shown across the coils of the machine primary control elements. Do not
install suppressors directly across the output contacts of the safety or interface module. In such a
configuration, it is possible for suppressors to fail as a short circuit.
Interface Module (1-channel EDM, with reset)—Generic Receiver Wiring