May 22, 2023
EZ-SCREEN SLS Safety Light Curtain Instruction Manual
31
•
•
•
•
•
•
Receiver
Emitter
Scan Code 2
Receiver
Emitter
Scan Code 1
Receiver
Emitter
Scan Code 2
Receiver
Emitter
Scan Code 1
Emitter
Receiver
Scan Code 1
Scan Code 2
Receiver 1
Emitter 1
Scan Code 1
Receiver 2
Emitter 2
Scan Code 2
Receiver 3
Emitter 3
Scan Code 2
Opaque Shield
WARNING:
Properly connect multiple pairs of sensors
Connecting multiple output signal switching devices (OSSD) safety outputs to one interface mod-
ule or otherwise parallel OSSD outputs can result in serious bodily injury or death, and is prohibit-
ed.
Do not connect multiple pairs of sensors to a single device.
WARNING:
Use a scan code
If you do not use a scan code, a receiver can synchronize to the signal from the wrong emitter, re-
ducing the safety function of the light curtain and creating an unsafe condition that could result in
serious injury or death.
Configure adjacent systems to use different scan codes (for example, set one system to use scan
code 1 and the other system to use scan code 2). Perform a trip test to confirm the light curtain
function.
Two systems installed in a horizontal plane
Figure 9.
Two or three systems stacked (or alternate re-
ceiver/emitter positions)
Figure 10.
Two systems installed at right angles
Figure 11.
Multiple systems installed in a line
Figure 12.
© Banner Engineering Corp.
Содержание EZ-SCREEN SLS
Страница 16: ...May 22 2023 EZ SCREEN SLS Safety Light Curtain Instruction Manual 16 Banner Engineering Corp...
Страница 52: ...Blank page 52...
Страница 68: ...Blank page 68...
Страница 90: ...Blank page 90...
Страница 102: ...Blank page 102...
Страница 106: ...Blank page 106...
Страница 114: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...