Figure 18. Optical alignment using the LAT-1-LP
Component 2 (Mirror)
Component 3 (Mirror)
Component 4 (Receiver)
Component 1 (Emitter)
Figure 19. Corner Mirror Alignment
6.3.5 Mute Configuration
1. From either normal operation or a power OFF condition, set the first and fourth DIP switches (T/L and the second
Red Res) both to the left (Trip operation and Reduced Resolution On positions). See
(p. 64).
2. Set the second and third DIP switches (Red Res and the second T/L) both to the right (Reduced Resolution Off and
Latch positions).
3. The receiver should now either be in a lockout condition or power is still OFF.
4. If power is Off: Apply power. The receiver display should now alternate between the Scan Code (C1 or C2) and the
mute configuration option currently set (01-08, factory default is 06). It will do this for three cycles, then display only
the mute configuration option (1-8). A corresponding number of green indicators will match the number shown on
the display. The Status indicator will be red, and all other indicators will be off.
If the receiver had been in normal operation in step 1: perform a system reset as described in
(p.
76). The receiver display should now show the mute configuration option currently set (1-8, factory default is 6). A
corresponding number of green indicators will match the number shown on the display. The Status indicator will be
red, and all other indicators will be off.
5. Select the desired mute configuration option: (see
• Toggling the Invert Display switch will sequence through the mute configuration options. The initial Invert
switch setting does not matter.
• For the Invert switch setting shown below (Invert Display off), move the switch to the left, then back to the
right (original setting). The mute configuration will sequence to the next option. The display and number of
green indicators will change accordingly. Repeat this until the desired mute configuration option is reached.
6. When the desired mute configuration option is reached, lock in the mute configuration by setting the DIP switches
for normal operation (see
(p. 64)).
Note: 10 minutes is allowed for setting the mute configuration before a lockout condition will
(p. 78).
7. Perform a valid reset sequence or cycle power.
EZ-SCREEN Low-Profile System with Integral Muting
38
www.bannerengineering.com - Tel: + 1 888 373 6767