Receiver
Emitter
Scan Code 2
Receiver
Emitter
Scan Code 1
a. Two systems in a horizontal plane
Receiver
Emitter
Scan Code 2
Receiver
Emitter
Scan Code 1
b. Two or three systems stacked (or alternate receiver/
emitter positions)
Emitter
Receiver
Horizontal
Receiver
Horizontal
Emitter
Scan Code 1
Scan Code 2
c. Two systems at right angles
Receiver 1
Emitter 1
Scan Code 1
Receiver 2
Emitter 2
Scan Code 2
Receiver 3
Emitter 3
Scan Code 2
Opaque Shield
d. Multiple systems
Figure 10. Installation of Multiple Systems
WARNING:
• Use a scan code
• If you do not use a scan code, a receiver can synchronize to the signal from the wrong emitter,
reducing the safety function of the light screen and creating an unsafe condition that could result
in serious injury or death.
• Configure adjacent systems to use different scan codes (for example, set one system to use scan
code 1 and the other system to use scan code 2). Perform a trip test to confirm the light screen
function.
5.3 Mounting System Components
5.3.1 Overview of Emitter/Receiver Mounting Hardware
Mounting Hardware
Emitter/receiver pairs can be spaced from 0.1 m (4 in) to 7 m (23 ft) apart. This distance is reduced if corner mirrors are
used.
EZ-SCREEN Low-Profile System with Integral Muting
28
www.bannerengineering.com - Tel: + 1 888 373 6767