Callout
Description
F
QS18VP6LPQ8 (4-pin Euro) sensors shown in figure. Other sensors or switches may be used.
13.1.6 4 and 5-Pin M12/Euro QD Cordsets
Table 12: 4-Pin Cordsets
Model
Length
Banner Cordset Pinout/Color Code
M12/Euro Connector (female face view)
DELPEF-40D
0.05 m (2.4 in)
QD pin
Function
1
N.C.
2
N.C.
3
0 V dc
4
Mute Status
2
3
4
1
DELPEF-41D
0.3 m (1 in)
DELPEF-43D
1 m (3.3 in)
DELPEF-48D
2.5 m (8 in)
DELPEF-415D
4.5 m (15 ft)
DELPEF-425D
7.6 m (25 ft)
DELPEF-450D
15.2 m (50 ft)
DELPEF-475D
22.8 m (75 ft)
DELPEF-4100D
30.4 m (100 ft)
Table 13: 5-Pin Cordsets
Model
Length
Banner Cordset Pinout/Color Code
M12/Euro Connector (female face view)
DELPEF-50D
0.05 m (2.4 in)
QD pin
Function
1
Reset Status
2
OSSDs Off
3
0 V dc
4
OSSDs On
5
Mute Status
2
3
4
1
5
DELPEF-51D
0.3 m (1 in)
DELPEF-53D
1 m (3.3 in)
DELPEF-58D
2.5 m (8 in)
DELPEF-515D
4.5 m (15 ft)
DELPEF-525D
7.6 m (25 ft)
DELPEF-550D
15.2 m (50 ft)
DELPEF-575D
22.8 m (75 ft)
DELPEF-5100D
30.4 m (100 ft)
13.2 Interface Modules
IM-T-..A interface modules provide forced-guided, mechanically-linked relay (safety) outputs for the EZ-SCREEN LPM
System See the Banner datasheet for more information.
Model
Description
Datasheet
IM-T-9A
Interface module, 3 normally open (N.O.) redundant-output 6 amp contacts, removable screw
terminals
IM-T-11A
Interface module, 2 normally open (N.O.) redundant-output 6 amp contacts, plus 1 normally closed
(N.C.) auxiliary contact, removable screw terminals
SR-IM-9A
Interface module, 3 normally open (N.O.) redundant-output 6 amp contacts, spring clamp terminals
SR-IM-11A
Interface module, 2 normally open (N.O.) redundant-output 6 amp contacts, plus 1 normally closed
(N.C.) auxiliary contact, spring clamp terminals
EZ-SCREEN Low-Profile System with Integral Muting
88