background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Summary of Contents for SlimPAR PRO

Page 1: ...User Manual ...

Page 2: ...Control Panel Operation 9 Menu Map 9 DMX Linking 10 Configuration DMX 10 D Fi USB Connectivity 10 Configuration D Fi USB 10 DMX Personality and Starting Address 11 DMX Channel Assignments and Values 11 12CH 11 7 CH 12 6 CH 12 Configuration Standalone 13 Automatic Programs 13 Auto Program Speed 13 Sound Active Mode 13 Sound Sensitivity 13 Preset Color Mode 13 Custom Color Mixing 13 Dimmer Speed 13 ...

Page 3: ...ration information Not following these instructions may make the product not work cause damage to the product or cause harm to the operator Important installation or configuration information The product may not function correctly if this information is not used Useful information Disclaimer Chauvet believes that the information contained in this manual is accurate in all respects However Chauvet ...

Page 4: ...to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots on the product s housing ar...

Page 5: ...verview WARNING DO NOT plug anything other than a D Fi USB into the USB port Doing so may cause damage to the product DMX In Out Power In Microphone D Fi USB Port Power Out Safety Cable Pass Through Fuse Holder Display Menu Buttons Back Panel View Front View Lenses IR Sensor ...

Page 6: ...Page 6 of 19 SlimPAR Pro H USB User Manual Rev 2 Product Dimensions 10 in 253 mm 11 4 in 290 mm 3 9 in 98 mm ...

Page 7: ... rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement 1 Wedge the tip of a flat head screwdriver into the slot of the fuse holder 2 Pry the fuse holder out of the housing 3 Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating 4 Insert the fuse holder back in place and reconnect power Disconnect the product from the power outlet bef...

Page 8: ...ecurely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When power linking multiple products mount the products close enough for power linking cables to reach The bracket adjustment knobs allow for directional adjustment when aiming the product to the desired angle Only loosen or tighten the bracke...

Page 9: ...a menu option or a selected value Menu Map Main Level Programming Levels Description 6 CH d001 512 6 channel DMX mode 7 CH d001 512 7 channel DMX mode 12CH d001 512 12 channel DMX mode C C1 63 Static colors P automatic P1 6 color program snap P2 6 color program pulse P3 32 color program snap P4 32 color program fading S S 1 100 Program speed for P1 P4 Snd sound active Snd1 6 color program sound ac...

Page 10: ...auvet DJ Simply set the product s DMX Personality and DMX Address set the DIP switch D Fi receiving transmitting channel then plug it into the D Fi USB port WARNING DO NOT plug anything other than a D Fi USB into the USB port Doing so may cause damage to the product Once plugged in the D Fi USB will take over the product Wired DMX manual display control menu buttons and IRC will be unavailable unt...

Page 11: ...lues 12CH Channel Function Value Percent Setting 1 Dimmer 000 255 0 100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 Amber 000 255 0 100 6 White 000 255 0 100 7 UV 000 255 0 100 8 Strobe 000 015 No function 016 255 Strobe slow to fast 9 Color Macros Overrides Ch 2 7 000 015 No function 016 255 Color macros 10 Mode 000 031 No function 032 063 Pulse effect 0 100 CH2 7 must be act...

Page 12: ...0 255 0 100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 Amber 000 255 0 100 6 White 000 255 0 100 7 UV 000 255 0 100 6 CH Channel Function Value Percent Setting 1 Red 000 255 0 100 2 Green 000 255 0 100 3 Blue 000 255 0 100 4 Amber 000 255 0 100 5 White 000 255 0 100 6 UV 000 255 0 100 ...

Page 13: ...ogram Snd1 or Snd2 4 Press ENTER The product will only respond to low frequencies of music bass and drums Sound Sensitivity To change the sound sensitivity on the SlimPAR PRO H USB follow the instructions below 1 Press MENU repeatedly until SenS shows on the display 2 Use UP and DOWN to increase or decrease the sound sensitivity u 0 100 3 Press ENTER The product will return to the last selected mo...

Page 14: ...SITIVITY on the IRC 6 2 Press or to increase or decrease the sound sensitivity Manual Color Control To choose a specific color with the IRC 6 1 Press MANUAL on the IRC 6 2 Press any number between 0 9 to choose your color To manually control the RGB percentage 1 Press MANUAL on the IRC 6 2 Press R red G green B blue A amber UV P UV or W white to choose your color 3 Press or to increase or decrease...

Page 15: ...from the master Do not connect more than 31 slaves to the master Master Slave Mode D Fi USB The D Fi USB allows a single SlimPAR PRO H USB product the master to control the actions of one or more SlimPAR PRO H USB products the slaves without the need of a DMX controller or DMX cables The master transmitter product will be set to operate in either Stand Alone mode or with the IRC 6 while the slave ...

Page 16: ...cy To clean the product follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents 4 Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint free ...

Page 17: ...er linking current products 8 A 5 products 8 A 10 products Fuse F 2 A 250 V F 2 A 250 V Power I O U S Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison U S Local plug Light Source Type Power Lifespan LED 10 W 50 000 hours Color Quantity Current Hex color RGBAW UV 12 2 4 A Photometrics Parameter Value Strobe Rate 0 to 31 Hz Beam Angle 24 Fiel...

Page 18: ...chnical Support office and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return Send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet wil...

Page 19: ...ing eu World Wide Web www chauvetlighting eu General Information Chauvet Europe Ltd Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk MEXICO General Information Chauvet Mexico Address Av Santa Ana 30 Parque Industrial Lerma Lerma Mexi...