background image

Part Number: 7067M1220-1.1.0 Rev: B

Released: 2017-06

Source 4

WRD

PAR and PARNel

®

 Fixture Bodies

Installation and User Manual

Version 1.1.0

Summary of Contents for Source 4WRD

Page 1: ...Part Number 7067M1220 1 1 0 Rev B Released 2017 06 Source 4WRD PAR and PARNel Fixture Bodies Installation and User Manual Version 1 1 0 ...

Page 2: ...All other trademarks both marked and not marked are the property of their respective owners This product is protected by one or more of the following U S Patents US 9 261 241 and 9 273 831 ETC intends this document whether printed or electronic to be provided in its entirety This product is intended for professional use only Read this entire document before using this product ...

Page 3: ...ation 8 Install Source 4WRD LED 8 Attach C clamp and safety cable 9 Connect cables 10 DMX pinout 11 User interface 11 Error codes 11 Set up the fixture 12 Set the angle within the yoke 12 Use the color frame 12 Loosen the Z adjustment knob 12 Adjust the focus knob PARNel fixtures only 13 PAR lenses 14 Change a PAR lens 15 PARNel lenses 16 Change front PARNel lens 16 ...

Page 4: ...ii Table of Contents Cleaning and maintenance 18 Clean the fixture 18 Store the fixture 18 Clean the lenses 19 Clean the reflector 19 ...

Page 5: ...l fixture The fixture produces about 20 more flux than a 750W long life Source Four PAR while consuming only 155W of power and it can be line dimmed as well as DMX dimmed WARNING The Source 4WRD PAR or PARNel fixture is not user serviceable Field modification of the fixture will void your ETC warranty Source 4WRD LED not included Color frame Lens Lens rotating ring Tabs Color frame holder Yoke Col...

Page 6: ...e this fixture if glass lens is deeply scratched or cracked Damaged lenses must be replaced To prevent wiring damage or abrasion do not expose wiring to edges of sheet metal or other sharp objects Use the fixture in dry locations only where humidity does not exceed 90 percent non condensing These fixtures are not intended for outdoor use Mount and support the fixture only by the primary suspension...

Page 7: ...lation Contact a qualified electrician WARNING RISK OF FIRE OR ELECTRIC SHOCK Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire WARNING To prevent wiring damage or abrasion do not expose wiring to edges of sheet metal or othe...

Page 8: ...retical max draw Recommended two 2 fixtures per dimmed circuit D20 module Max of 14 fixtures per non dimmed circuit R20 module If using in DMX mode Connect fixture to relay constant power or dimmer with regulation off and parked at full LEDs 4 CREE LED modules 30 000 hour estimated L70 rating life test in progress results pending Optical Includes a flat lens Compatible with all ETC Source Four PAR...

Page 9: ...ollowing tables apply to ETC Sensor control modules including CEM CEM and CEM3 Note You may need to adjust dimmer settings for optimal fixture control Note In CEM set Max Scale to 140V to guarantee that regulation is off CEM and CEM3 Parameter Value Curve Mod Square Threshold 1 Min Scale 6V Max Scale 140V Regulation OFF Preheat Disabled DC Prevent OFF Inrush Protect OFF Scale Load 100 CEM Classic ...

Page 10: ...g measured output spectrum These numbers may fluctuate slightly from fixture to fixture This is a normal characteristic of white LEDs and this kind of variation is highly unlikely to be apparent in most applications Note With AC dimming line dimmed mode performance may vary based on the control settings of the dimmer used For this reason ETC recommends using AC dimming for level setting or for arc...

Page 11: ...nd installation type Other components in your system Unison other consoles etc Americas United Kingdom ETC Inc ETC Ltd Technical Services Department Technical Services Department 3031 Pleasant View Road 26 28 Victoria Industrial Estate Middleton WI 53562 Victoria Road 800 775 4382 USA toll free London W3 6UU England 1 608 831 4116 44 0 20 8896 1000 service etcconnect com service etceurope com Asia...

Page 12: ...adjustment knob toward PEAK until the knob is loosened This sets the LED light source into the appropriate position within the Source 4WRD PAR or PARNel fixture WARNING RISK OF FIRE OR ELECTRIC SHOCK Install the Source 4WRD LED only onto a Source 4WRD PAR or PARNel Fixture Body or Source Four ellipsoidal fixture body CAUTION Do not touch LED optic domes Do not clean LED optic domes with anything o...

Page 13: ...ate the yoke to the desired position 4 Tighten the pan screw to lock the fixture 5 Connect the safety cable 6 Tighten C clamp pipe bolt to 15 20 ft lbs 20 27 Nm approximately finger tight plus up to one quarter turn 7 Tighten the yoke pivot bolt to 5 10 ft lbs 6 7 Nm approximately finger tight plus up to one eighth turn CAUTION Do not exceed 25 ft lbs 33 Nm while tightening the C clamp pipe bolt D...

Page 14: ...k protocols and should not be connected to a system network Up to 32 fixtures can be connected together into a daisy chain 3 Connect fixture to power source Note Make sure your dimmer is out of regulated mode for optimum performance See Sensor dimmer settings on page 5 for recommended dimmer settings Note Connecting both power and data from a SmartBar 1 to a Source 4WRD PAR or PARNel fixture may c...

Page 15: ...wing error codes may be seen on the fixture user interface indicates the fixture has gone into over temperature protection Reset the fixture to clear the code For DMX mode Return the DMX control to 0 For AC mode Remove the fixture from power for five seconds and then restore power indicates the fixture has gone into under temperature protection Allow the fixture to warm to a minimum of 5 C 41 F Fl...

Page 16: ...ays while gently pulling backwards 2 Insert the color frame 3 Lock the retaining clip by pushing sideways while gently pushing forward Loosen the Z adjustment knob Turn the Z adjustment knob toward PEAK until the knob is loosened This sets the LED light source into the appropriate position within the Source 4WRD PAR or PARNel fixture After the knob is loosened no additional adjustments are needed ...

Page 17: ...sion on a PARNel lens loosen or tighten the focus knob screw located on the bottom of the lens CAUTION The focus knob does not rotate 360 Do not attempt to exceed limit Focus knob in flood position Focus knob in spot position 45 field angle 25 field angle Focus knob screw Focus knob ...

Page 18: ...spread by the lens texture MFL WFL NSP VNSP Very narrow spot Clear glass 15 Round beam shape Narrow spot Stipple glass slight diffuse texture 19 Round beam shape Medium flood Fewer facets sized 6 x 22mm 21 x 34 Oblong beam shape Wide flood Many facets sized 6 x 12mm 30 x 51 Oblong beam shape XWFL Optional Extra wide or buxom lens Molded borosilicate lens multi faceted 60 Round beam shape ...

Page 19: ...Tilt the front of the fixture down at least 45 4 Press the spring clip with your finger to release the lens See figure at right 5 Allow the lens to drop forward from under the clip 6 When the lens drops remove your finger allowing the lens to slide forward until it rests on the lens catchers See figure at right 7 Carefully remove the lens CAUTION Never operate the fixture without a lens in place W...

Page 20: ... PARNel lenses PARNel lenses come in two versions The wave clear lens is in a fixed position in the rear of the fixture The wave stippled lens is in the rotating ring at the front of the fixture The wave surfaces face each other Change front PARNel lens Replace lenses if they become cracked or badly scratched Note Installing the lens with the convex side out will not impair the optics but it will ...

Page 21: ...y remove the lens Install a front lens 1 Position the fixture with the front of the unit lens side facing you and tilted slightly upward 2 Rotate the focus knob to the full spot position 3 Hold the lens by the edge and position it so the convex side faces the rear of the fixture 4 From the top of the fixture slide the lens behind the lens catchers and position it behind the tabs on the bottom of t...

Page 22: ...tack as part of regular fixture maintenance Store the fixture When not installed on the Source 4WRD PAR or PARNel Fixture Body store the Source 4WRD LED in a dust resistant plastic bag Store the Source 4WRD PAR or PARNel fixture at temperatures of 5 C 41 F or higher If you must store the fixture below 5 C 41 F make sure it is in an upright position as shown to the right Allow it to warm to room te...

Page 23: ...ve the LED housing by loosening the attachment screw and pulling the LED housing straight out See image on page 8 3 Remove dust with a blast of oil free air or wipe with a clean lint free cloth Isopropyl alcohol distilled water or a 50 50 mixture of each can be used to clean the glass surface 4 Replace the lens See Install a lens on page 16 5 Reinstall the Source 4WRD LED and tighten the attachmen...

Page 24: ...ice UK service etceurope com Holzkirchen DE Tel 49 80 24 47 00 0 Service DE techserv hoki etcconnect com Hong Kong Tel 852 2799 1220 Service Asia service etcasia com Web etcconnect com Copyright 2017 Electronic Theatre Controls Inc All Rights Reserved Product information and specifications subject to change ETC intends this document to be provided in its entirety 7067M1220 1 1 0 Rev B Released 201...

Reviews: