background image

 

 
 
 
 
 
 

User Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ilumipod 54g2 ip

Page 1: ...User Manual ...

Page 2: ...ritten consent Document Printing For better results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure your printer to scale the content of this document to A4 paper Disclaimer ILUMINARC believes that the information contained in this manual is accurate in all respects However ILUMINARC assumes no responsibility for any error or omis...

Page 3: ...l Safety 2 Mounting and Installation 2 Power and Wiring 2 Operation 2 2 Product Description 3 Features 3 Options 3 Product Overview 4 Product Dimensions 5 3 Installation 6 Mounting 6 Orientation 6 Installation 6 AC Power 7 Power Consumption 7 AC Plug 7 Power Wiring 7 DMX Linking 8 DMX Modes 8 Signal Wiring 8 Protocol Connectivity 8 Controllers 9 DMX Controller 9 Ilumicode addresser 10 ...

Page 4: ...Dimmer 12 Color 12 Whites Setting 12 Reset to Factory Settings 12 Menu Map Ilumicode 13 DMX Values 14 ARC FULL 14 ARC 1 14 ARC 1 D 14 SOLID 14 SPECIAL 2 15 ARC 2 15 ARC 2 D 15 5 Technical Information 16 Product Maintenance 16 Product Repairs 16 Photometrics 17 LED Disclaimer 18 LED Life 18 LED Binning 18 Color Rendering Index CRI 18 Return Procedure 19 Contact Us Error Bookmark not defined Technic...

Page 5: ...rier is responsible for any damage incurred during shipping Therefore if the received merchandise appears to have been damaged during shipping the customer must submit the damage report and any related claims to the carrier not ILUMINARC The customer must submit the report upon receipt of the damaged merchandise Failure to do so in a timely manner may invalidate the customer s claim with the carri...

Page 6: ...n 1 m for more than 30 minutes Not for permanent outdoor installation in locations with extreme environmental conditions This includes but is not limited to o Exposure to a marine saline environment within 3 miles of a saltwater body of water o Where the normal high or low temperatures of the location exceed the temperature ranges in this manual o Locations that are prone to flooding or being buri...

Page 7: ... 3 channel RGB control 4 channel RGB dimmer 4 channel RGBW 5 channel RGBW dimmer 7 channel RGB dimmer color macro strobe dimmer speed 8 channel RGBW dimmer color macro strobe dimmer speed Pre programmed color macros RGBW color mixing with or without DMX control Built in color temperature presets Five distinct dimming curves Adjustable bracket Impact resistant glass lens cover Cast aluminum IP67 ho...

Page 8: ...Product Description 4 Ilumipod 54g2 IP User Manual Rev 2 Product Overview Side View Rear View Front View Data In Out Power In 3 W LEDs Adjustment Knob Mounting Bracket ...

Page 9: ...Product Description Ilumipod 54g2 IP User Manual Rev 2 5 Product Dimensions 11 54 in 293 mm 11 18 in 284 mm 9 76 in 248 mm 16 46 in 418 mm 17 72 in 450 mm ...

Page 10: ...guration and maintenance Installation The Ilumipod 54g2 has 3 mounting points on the mounting bracket to secure it to almost any surface provided that it can support the product s weight ILUMINARC recommends following the general guidelines below when mounting the Ilumipod 54g2 IP When selecting an installation location consider ease of access to the product for operation programming adjustments a...

Page 11: ...ine the power requirements for the Ilumipod 54g2 IP refer to the label affixed to the side of the product Alternatively you may refer to the Technical Specifications The listed current rating indicates the maximum current draw during normal operation AC Plug The Ilumipod 54g2 IP comes with a bare ended power input cord for hardwire installation Use the table and the illustration below to wire a pl...

Page 12: ... If you are not familiar with the DMX standard or if you need information about the DMX cables needed to link the Ilumipod 54g2 IP to a DMX controller you may download the DMX Primer from the ILUMINARC website at http www iluminarc com reports dmx primer DMX Modes The Ilumipod 54g2 IP uses the standard DMX data connection for all of its DMX personalities Refer to the Introduction chapter for a bri...

Page 13: ... provide information on how to connect these products to the corresponding controllers The instructions to operate these products with each of the above controllers are in the Operation section of this manual DMX Controller The Ilumipod 54g2 IP can work with a standard DMX controller The channel assignments will depend on the chosen personality see the corresponding Menu Map section and the DMX ad...

Page 14: ...ed signal amplifier The RDM2go which includes a built in ilumicode addresser along with many other useful features is now available Ilumicode addresser The Ilumipod 54g2 IP uses the Ilumicode addresser Ilumicode for configuration purposes The diagram below shows how to connect the Ilumicode to this product This connection will control multiple products at the same time all having the same DMX addr...

Page 15: ... menu list and decreases the numeric value when in a function POWER Turns the unit on The unit will turn off automatically after 30 seconds of inactivity Control Options You can set the Ilumipod 54g2 IP start address in the 001 512 DMX range This allows for the control of up to 64 products in the 8 channel Special 2 personality Programming Carry out all the programming procedures indicated below f...

Page 16: ...near slow DIM4 Non linear slowest Color 1 Go to SETTINGS COLOR 2 Select the color method OFF RGBTOW or UC Details OFF When the RGB faders are all set to 255 the output is maximum RGB TO W When the RGB faders are all set to 255 the output is the selected White color see Whites Setting UC When the RGB faders are all set to 255 the output matches the same color output of previous versions of this pro...

Page 17: ...nel RGBW control dimmer color macro strobe dimmer speed CALIB WHITE 01 11 RED GREN BLUE 000 255 Determines the white balance for the color macros RGB Determines the white balance when RGBTOW is active DIMMER OFF Dimmer works in linear mode DIM 1 Dimmer works in non linear mode from fast to slow DIM 2 DIM 3 DIM 4 STATIC RED 0 255 Configures the static color and effects GREN BLUE COOL STRB SETTINGS ...

Page 18: ...G 0 100 B 0 100 R 100 0 G 100 0 B 100 R 100 G 100 B 100 White 1 White 2 White 3 White 4 White 5 White 6 White 7 White 8 White 9 White 10 White 11 6 Strobe 000 ó 005 006 ó 255 No function Slow Fast 7 Dimmer Speed 000 ó 009 010 ó 029 030 ó 069 070 ó 129 130 ó 189 190 ó 255 Preset dimmer speed from display menu Linear dimmer Nonlinear dimming curve 1 fastest Nonlinear dimming curve 2 Nonlinear dimmin...

Page 19: ... B 100 0 R 100 G 0 100 B 0 100 R 100 0 G 100 0 B 100 R 100 G 100 B 100 W 100 White 1 White 2 White 3 White 4 White 5 White 6 White 7 White 8 White 9 White 10 White 11 7 Strobe 000 ó 005 006 ó 255 No function Slow Fast 8 Dimmer Speed 000 ó 009 010 ó 029 030 ó 069 070 ó 129 130 ó 189 190 ó 255 Preset dimmer speed from display menu Linear dimmer Nonlinear dimming curve 1 fastest Nonlinear dimming cur...

Page 20: ...product operates Damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the product s optics requiring more frequent cleaning To clean a product 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents and reachable internal components 4 Clean ...

Page 21: ...Technical Information Ilumipod 54g2 IP User Manual Rev 2 17 Photometrics ...

Page 22: ...consistencies related to CRI Results may vary depending on the environmental factors involved For this reason the U S Department of Energy DOE states that CRI should be considered as one point of reference among others in evaluating white LED products and systems The following is an excerpt of recommendations from the DOE 1 Identify the visual tasks to be performed under the light source If color ...

Page 23: ...Any shipping damage resulting from inadequate packaging will be the customer s responsibility Proper FedEx packing or double boxing are recommended Contact Us USA WORLD HEADQUARTERS General Information ILUMINARC Address 5200 NW 108th Avenue Sunrise FL 33351 Voice 954 923 3680 Fax 800 544 4898 Technical Support Voice 800 762 1084 Email support iluminarc com World Wide Web www iluminarc com EUROPE G...

Page 24: ...er 120 V 60 Hz 230 V 50 Hz Consumption 110 W 0 92 A 105 W 0 49 A Power I O Input Output Connectors Hard wired N A Cord plug Bare wired N A Light Source Type Power Lifespan LED 3 W 50 000 hours Color Quantity Current Red 15 930 mA Green 15 930 mA Blue 15 930 mA White 9 930 mA Photometrics Parameter Standard 30º Optics Illuminance 5 m 1 038 lux Beam angle 21 Field angle 40 Thermal Max External Tempe...

Page 25: ...Ilumipod 54g2 IP User Manual ...

Reviews: