background image

17

© Banner Engineering Corp. www.bannerengineering.com

C

ONTROLLER

 C

ONNECTIONS

 

FOR

 

THE

 DXMR110-8K

 

Figure 3: 

IO-Link configuration start page

Figure 4: 

IO-Link configuration to select Ethernet

Содержание DXMR110-8K

Страница 1: ...DXMR110 8K IO Link Master Instruction Manual April 10 2023 Banner Engineering Corp All rights reserved...

Страница 2: ...tion Backup Restore Mode 16 Configuring Connected Banner IO Link Devices DXMR110 8K 16 Chapter 5 Configuration Instructions 18 Set the Controller to use Authentication 18 Set the Web Services to Use A...

Страница 3: ...ons for the DXMR110 8K 32 File System and Archive Process 33 Update Your DXM Processor Firmware Using the Configuration Software 33 DXM Support Policy 33 Firmware Updates 33 Website Information 33 Fea...

Страница 4: ...DD IODD files contain information about identification device parameters process and diagnostic data communication properties and other details The IODD files for Banner IO link devices can be downloa...

Страница 5: ...Link device 2 IOL_AUTOSTART Digital Input The IO Link port functions as a standard digital input 3 DI_C Q Digital Output The IO Link port functions as a standard digital output 4 DO_C Q 1 3 Combining...

Страница 6: ...ize cabling and associated weight especially in weight critical applications such as robotics Flexible and Customizable Expanded internal logic controller with action rules and ScriptBasic programming...

Страница 7: ...ess the DXMR110 8K using the Modbus TCP IP protocol over Ethernet Standard Modbus TCP port 502 is used by the DXMR110 8K for all Modbus TCP IP requests All internal local registers are available to th...

Страница 8: ...Corp www bannerengineering com DXMR110 8K OVERVIEW Figure 1 DXMR110 8K Dimensions 145 0 mm 5 71 91 1 mm 3 59 11 X M12 x 1 0 2 X 4 5 M12 x 1 0 30 mm 1 18 25 mm 0 98 25 mm 0 98 25 mm 0 98 25 mm 0 98 40...

Страница 9: ...igure 1 DXMR110 8K IO Link Master ports Table 1 Ports 1 8 female connector Port 1 8 5 pin M12 Connector female Pin Wire Color Description 1 Brown bn 18 V DC to 30 V DC 2 White wh I Q digital in out 3...

Страница 10: ...ware from http www bannerengineering com For more information on using the DXM Configuration Software refer to the instruction manual p n 209933 Table 3 4 pin M2 female connector 4 pin M12 Power Conne...

Страница 11: ...tion Manual p n 209933 3 2 2 Configuring the DXMR110 8K Controller This section will walk you through the method of setting up the DXM Configuration Software and communicating with a connected DXM dev...

Страница 12: ...92 168 0 1 To connect to the device you need to be on the same subnet You can do this by accessing the control panel on your PC and accessing your Network Connections properties It is important to ens...

Страница 13: ...d cannot read the data If the permissions are set to Read Write the web server can read the data from the device and write to the device from the web 5 Click Modify Registers to save and apply the cha...

Страница 14: ...ation Tool unplug and re plug in the cable and recon nect the DXM to the software If the Application Status indicator is green the file upload is complete If the Application Status indicator is gray a...

Страница 15: ...he DXMR110 8K on page 6 For more information on the device registers and port settings of the DXMR110 8K IO Link Master refer to the DXMR110 8K IO Link Master IO Link Master Device Register Map p n 23...

Страница 16: ...a that must be maintained when power is turned off This register data is stored in a data flash component that has a limited write capability of 100 000 cycles so these registers should not be used as...

Страница 17: ...of write map timeouts 22107 Number of write map errors 22108 Write map success streak 22109 Number of passthrough successes API message passing statistics 22110 Number of passthrough timeouts 22111 N...

Страница 18: ...s parameters for the IO Link ports are set in the DXM Configuration Software and are saved in the XML configuration file Each port can have unique settings Figure 2 RTU Configuration screen for ports...

Страница 19: ...Mode If a port on the IO Link master is set to Backup Restore then the new device added to the IO Link port takes in the same device configuration as the device that was just replaced as the IO Link...

Страница 20: ...17 Banner Engineering Corp www bannerengineering com CONTROLLER CONNECTIONS FOR THE DXMR110 8K Figure 3 IO Link configuration start page Figure 4 IO Link configuration to select Ethernet...

Страница 21: ...tication screen STEP RESULT The first time you select Require Authentication a pop up box appears with additional instructions Since the data is not stored in the XML configuration file it is hidden f...

Страница 22: ...When programming an application in the DXMR110 8K first plan the overall data structure of the Local Registers The Local Registers are the main storage elements in the DXMR110 8K Everything goes into...

Страница 23: ...10 8K using an EDS file or by using the following parameters Assembly1 Originator to DXM Instance 112 456 bytes 228 words Assembly2 DXM to Originator Instance 100 456 bytes 228 words The Originator is...

Страница 24: ...k Master AOI is to provide quasi realtime read write access to all IO Link parameter data in the sensor Each Param eter Data AOI is specific to a given sensor IO Link Master AOIs v2 1 These files requ...

Страница 25: ...tries a message five times The five retry attempts immediately follow each other After all attempts are exhausted the register data packet is lost At the next sched uled time the DXMR110 8K attempts t...

Страница 26: ...across a variety of tools as a standard set of device information 6 2 DXM PROFINET IO Data Model The PROFINET IO data model is based on the typical expandable field device that has a backplane with sl...

Страница 27: ...uration 6 4 Slots and Modules for DXM PROFINET There are ten slots to accommodate the DXM Controller data It is important to note that the module placed in slot 2 corresponds to Port 1 the module plac...

Страница 28: ...gister End Direction 0x4D 0x01 ISDU 190 Byte Status 196 351 442 Bidirectional 196 200 291 0x4E 0x01 ISDU 80 Byte Status 86 351 396 86 200 245 Slot Module Description Slot 1 Banner IO Link Master Info...

Страница 29: ...eering com 2 Launch the Siemens TIA Portal v14 software 3 Click Open existing project 4 Select a project and open it 5 After the project is uploaded click Devices networks Figure 2 Devices and network...

Страница 30: ...ering Corp 6 5 2 Change the Device IP Address Follow these instructions to change the IP address of the DXM device using the Siemens TIA Portal v14 software Use these instructions as a basis if you ar...

Страница 31: ...t 11 Enter the IP address 12 Right click on the device icon and select Online diagnostics Figure 7 Online diagnostics menu and screen STEP RESULT The Online diagnostics windows displays 13 Select Assi...

Страница 32: ...If the DXM is restarted after it was discovered and configured by the PLC the DXM retains the IP address that was assigned to it using the LCD or software until after the PLC discovers the DXM and ass...

Страница 33: ...SMBR90S Stainless steel bracket 4x M4 07 pemnuts B Includes 2x M4 stainless steel hex head screws and flat washers Hole center spacing A 40 B 20 Hole size A 5 4 Pin Threaded M12 Cordsets Double Ended...

Страница 34: ...ge 2 Orange 3 White Blue 6 Blue 1 White Orange 2 White Blue 3 Orange 4 Blue STP M12D 415 4 57 m 15 ft STP M12D 430 9 14 m 30 ft 4 pin M12 D code Double ended Male Model Length Style Dimensions Pinout...

Страница 35: ...Port 6 Status Red green blue on port 7 IO Link Port 7 Status Red green blue on port 8 IO Link Port 8 Status Connections Nine integral 4 pin M12 female quick disconnects One integral 4 pin M12 male qui...

Страница 36: ...ETING THIS TASK After the file load is completed reboot the device by selecting DXM Reboot DXM To verify the firmware has been updated go to Tools Reprogram Get Device Information and verify the new v...

Страница 37: ...vice IMPORTANT Por favor descargue desde www bannerengineering com toda la documentaci n t cnica de los DXMR110 8K IO Link Master disponibles en m ltiples idiomas para detalles del uso adecuado aplica...

Страница 38: ...UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGI...

Отзывы: