Wiring Diagrams
NPN Models
PNP Models
Key
3
1
2
4
5
10-30V dc (Current Models)
12-30V dc (Voltage Models)
Input
Wire
Load
Load
+
–
D_Out
A_Out
3
1
2
4
5
10-30V dc (Current Models)
12-30V dc (Voltage Models)
Input
Wire
Load
Load
+
–
D_Out
A_Out
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
(6 = no connection)
NOTE: Open lead wires must be connected to a terminal block.
NOTE: When using multiple sensors in Master/Slave mode, the gray wires from each sensor should be
connected together. The remote programming function cannot be used.
Top Panel Interface
Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ
mode switch, CH1/CH2 switch, +/SET/- rocker button, dual red/green digital displays, and output LED(s).
RUN/PRG/ADJ Mode Switch
The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode.
•
RUN mode allows the sensor to operate normally and prevents unintentional programming
changes via the +/SET/- rocker button.
•
PRG mode allows the sensor to be programmed through the display-driven programming menu
(see
Program Mode
on page 6).
•
ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see
Adjust
Mode
on page 7).
CH1/CH2 Switch
The CH1/CH2 switch selects which output's parameters can be accessed and changed in the interface of
the display.
•
CH1 selects the Analog Output
•
CH2 selects the Discrete Output
+/SET/- Rocker Button
The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/
right. The SET position is engaged by clicking down the button while the rocker is in the middle position.
All three button positions are used during PRG mode to navigate the display-driven programming menu.
In ADJ mode, SET is used to perform TEACH/SET methods and +/- are used to manually adjust the
threshold(s). In CH1 RUN mode, the rocker button is used to view the analog endpoints and midpoint
signal values. The rocker button is disabled during CH2 RUN mode, except when using Window SET (see
Window SET
on page 9).
Red/Green Digital Displays
During RUN and ADJ modes, the Red display shows the signal level, and the Green display shows the
analog output in volts or milliamps when CH1 is selected or the threshold when CH2 is selected. During
PRG mode, both displays are used to navigate the display-driven programming menu.
DF-G3 Long Range Expert
™
Dual Display Fiber Amplifier with Analog Output
4
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 190340 Rev. B